4.8 Article

Magnetic resonance elastography plus Fibrosis-4 versus FibroScan-aspartate aminotransferase in detection of candidates for pharmacological treatment of NASH-related fibrosis

Journal

HEPATOLOGY
Volume 75, Issue 3, Pages 661-672

Publisher

WILEY
DOI: 10.1002/hep.32145

Keywords

-

Funding

  1. National Institute of Environmental Health Sciences [5P42ES010337]
  2. National Center for Advancing Translational Sciences [5UL1TR001442]
  3. Department of Defense's Peer-Reviewed Cancer Research Program [W81XWH-18-2-0026]
  4. National Institute of Diabetes and Digestive and Kidney Diseases [U01DK061734, R01DK106419, R01DK121378, R01DK124318, P30DK120515]
  5. National Heart, Lung, and Blood Institute [P01HL147835]
  6. National Institute on Alcohol Abuse and Alcoholism [U01AA029019]
  7. Uehara Memorial Foundation [201940021]

Ask authors/readers for more resources

The study compared the diagnostic accuracy of MEFIB and FAST for detecting significant fibrosis in NAFLD patients, finding that MEFIB had higher accuracy and supporting the use of a two-step strategy for detecting significant fibrosis in NAFLD.
Background and Aims Patients with NAFLD with significant hepatic fibrosis (Stage >= 2) are at increased risk of liver-related morbidity and are candidates for pharmacologic therapies. In this study, we compared the diagnostic accuracy of MEFIB (the combination of magnetic resonance elastography [MRE] and Fibrosis-4 [FIB-4]) and FAST (FibroScan-aspartate aminotransferase; combined liver stiffness measurement by vibration-controlled transient elastography, controlled attenuation parameter, and aspartate aminotransferase) for detecting significant fibrosis. Approach and Results This prospective cohort study included 234 consecutive patients with NAFLD who underwent liver biopsy, MRE, and FibroScan at the University of California San Diego (UCSD cohort) and an independent cohort (N = 314) from Yokohama City University, Japan. The primary outcome was diagnostic accuracy for significant fibrosis (Stage >= 2). The proportions of significant fibrosis in the UCSD and Yokohama cohorts were 29.5% and 66.2%, respectively. Area under the receiver operating characteristic curve (95% CI) of MEFIB (0.860 [0.81-0.91]) was significantly higher than that of FAST (0.757 [0.69-0.82]) in the UCSD cohort (p = 0.005), with consistent results in the Yokohama cohort (AUROC, 0.899 [MEFIB] versus 0.724 [FAST]; p < 0.001). When used as the rule-in criteria (MEFIB, MRE >= 3.3 kPa and FIB-4 >= 1.6; FAST >= 0.67), the positive predictive value for significant fibrosis was 91.2%-96.0% for MEFIB and 74.2%-89.2% for FAST. When used as the rule-out criteria (MEFIB, MRE < 3.3 kPa and FIB-4 < 1.6; FAST <= 0.35), the negative predictive value for significant fibrosis was 85.6%-92.8% for MEFIB and 57.8%-88.3% for FAST. Conclusions MEFIB has higher diagnostic accuracy than FAST for significant fibrosis in NAFLD, and our results support the utility of a two-step strategy for detecting significant fibrosis in NAFLD.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available