4.2 Article

Structural heart disease, not the right ventricular pacing site, determines the QRS duration during right ventricular pacing

Journal

HEART AND VESSELS
Volume 36, Issue 12, Pages 1870-1878

Publisher

SPRINGER
DOI: 10.1007/s00380-021-01881-4

Keywords

Electrical dyssynchrony; Heart failure; Pacing; QRS duration; Right ventricle

Ask authors/readers for more resources

This study found that predictors of QRS prolongation during RV apical pacing include baseline QRS duration, interventricular septum thickness, left atrial diameter, and E/e' ratio. The QRS duration during RV pacing is largely influenced by underlying structural heart diseases rather than the pacing site.
Right ventricular (RV) pacing causes changes in the heart's electrical and mechanical activation patterns. The QRS duration is a useful surrogate marker of electrical dyssynchrony; a longer QRS duration during RV pacing indicates poor prognosis. However, the mechanisms underlying a longer QRS duration during RV pacing remain unclear; hence, we investigated factors predicting QRS prolongation during RV pacing. We enrolled 211 patients who underwent catheter ablation for supraventricular tachyarrhythmia and showed no bundle branch block. Three-dimensional mapping for the QRS duration during RV pacing from the RV outflow to RV apex was performed, and differences in the QRS duration were analyzed. The predisposing factors causing QRS > 160 ms during RV apical pacing were also analyzed. The QRS durations at baseline and during RV pacing from the RV outflow and at the RV apex were 85.0 +/- 7.5 ms, 163.7 +/- 17.1 ms, and 156.2 +/- 16.1 ms, respectively. With respect to the QRS duration, there was a significant correlation between RV outflow and RV apical pacing (r = 0.658, p < 0.001). Difference in the QRS duration between the RV outflow and RV apex in each patient was only 12.5 +/- 10.4 ms. Logistic multivariable regression analysis identified baseline QRS duration [odds ratio (OR) 1.24, 95% confidence interval (CI) 1.15-1.33, p < 0.01], interventricular septum thickness (OR 1.20, 95% CI 1.02-1.40, p = 0.025), left atrial diameter (OR 1.08, 95% CI 1.01-1.16, p = 0.024), and E/e' (OR 1.23, 95% CI 1.12-1.35, p < 0.01) as significant predictors of QRS prolongation during RV apical pacing. The QRS duration during RV pacing largely depends not on the pacing site, but on the underlying structural heart diseases.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available