4.8 Article

Artificial intelligence and colonoscopy experience: lessons from two randomised trials

Journal

GUT
Volume 71, Issue 4, Pages 757-765

Publisher

BMJ PUBLISHING GROUP
DOI: 10.1136/gutjnl-2021-324471

Keywords

colonoscopy; adenoma; artificial Intelligence; colorectal cancer; screening

Ask authors/readers for more resources

Artificial intelligence assistance during colonoscopy can increase adenoma detection rate (ADR) and related polyp parameters in less experienced examiners compared to the control group. The level of examiner experience does not play a significant role in determining ADR, as shown in this study.
Background and aims Artificial intelligence has been shown to increase adenoma detection rate (ADR) as the main surrogate outcome parameter of colonoscopy quality. To which extent this effect may be related to physician experience is not known. We performed a randomised trial with colonoscopists in their qualification period (AID-2) and compared these data with a previously published randomised trial in expert endoscopists (AID-1). Methods In this prospective, randomised controlled non-inferiority trial (AID-2), 10 non-expert endoscopists (<2000 colonoscopies) performed screening/surveillance/diagnostic colonoscopies in consecutive 40-80 year-old subjects using high-definition colonoscopy with or without a real-time deep-learning computer-aided detection (CADe) (GI Genius, Medtronic). The primary outcome was ADR in both groups with histology of resected lesions as reference. In a post-hoc analysis, data from this randomised controlled trial (RCT) were compared with data from the previous AID-1 RCT involving six experienced endoscopists in an otherwise similar setting. Results In 660 patients (62.3 +/- 10 years; men/women: 330/330) with equal distribution of study parameters, overall ADR was higher in the CADe than in the control group (53.3% vs 44.5%; relative risk (RR): 1.22; 95% CI: 1.04 to 1.40; p<0.01 for non-inferiority and p=0.02 for superiority). Similar increases were seen in adenoma numbers per colonoscopy and in small and distal lesions. No differences were observed with regards to detection of non-neoplastic lesions. When pooling these data with those from the AID-1 study, use of CADe (RR 1.29; 95% CI: 1.16 to 1.42) and colonoscopy indication, but not the level of examiner experience (RR 1.02; 95% CI: 0.89 to 1.16) were associated with ADR differences in a multivariate analysis. Conclusions In less experienced examiners, CADe assistance during colonoscopy increased ADR and a number of related polyp parameters as compared with the control group. Experience appears to play a minor role as determining factor for ADR.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available