4.6 Article

Artificial intelligence in computed tomography for quantifying lung changes in the era of CFTR modulators

Journal

EUROPEAN RESPIRATORY JOURNAL
Volume 59, Issue 3, Pages -

Publisher

EUROPEAN RESPIRATORY SOC JOURNALS LTD
DOI: 10.1183/13993003.00844-2021

Keywords

-

Funding

  1. IdEx [ANR-10-IDEX-03-02]
  2. French Society of Radiology

Ask authors/readers for more resources

This study aimed to validate a fully automated artificial intelligence (AI)-driven scoring system of CF lung disease severity. The results showed that the AI-driven volumetric quantification had good correlations with visual imaging scoring and pulmonary function tests, providing a robust outcome for CF-related disease in the era of effective CF transmembrane conductance regulator modulator therapy.
Background Chest computed tomography (CT) remains the imaging standard for demonstrating cystic fibrosis (CF) airway structural disease in vivo. However, visual scoring systems as an outcome measure are time consuming, require training and lack high reproducibility. Our objective was to validate a fully automated artificial intelligence (AI)-driven scoring system of CF lung disease severity. Methods Data were retrospectively collected in three CF reference centres, between 2008 and 2020, in 184 patients aged 4-54 years. An algorithm using three 2D convolutional neural networks was trained with 78 patients' CT scans (23 530 CT slices) for the semantic labelling of bronchiectasis, peribronchial thickening, bronchial mucus, bronchiolar mucus and collapse/consolidation. 36 patients' CT scans (11435 CT slices) were used for testing versus ground-truth labels. The method's clinical validity was assessed in an independent group of 70 patients with or without lumacaftor/ivacaftor treatment (n=10 and n=60, respectively) with repeat examinations. Similarity and reproducibility were assessed using the Dice coefficient, correlations using the Spearman test, and paired comparisons using the Wilcoxon rank test. Results The overall pixelwise similarity of AI-driven versus ground-truth labels was good (Dice 0.71). All AI-driven volumetric quantifications had moderate to very good correlations to a visual imaging scoring (p<0.001) and fair to good correlations to forced expiratory volume in 1 s % predicted at pulmonary function tests (p<0.001). Significant decreases in peribronchial thickening (p=0.005), bronchial mucus (p=0.005) and bronchiolar mucus (p=0.007) volumes were measured in patients with lumacaftor/ivacaftor. Conversely, bronchiectasis (p=0.002) and peribronchial thickening (p=0.008) volumes increased in patients without lumacaftor/ivacaftor. The reproducibility was almost perfect (Dice >0.99). Conclusion AI allows fully automated volumetric quantification of CF-related modifications over an entire lung. The novel scoring system could provide a robust disease outcome in the era of effective CF transmembrane conductance regulator modulator therapy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available