Comparison of radiation exposure between endoscopic ultrasound-guided drainage and transpapillary drainage by endoscopic retrograde cholangiopancreatography for pancreatobiliary diseases

Journal

DIGESTIVE ENDOSCOPY
Volume 34, Issue 3, Pages 579-586

Publisher

WILEY
DOI: 10.1111/den.14060

Keywords

endoscopic retrograde cholangiopancreatography; fluoroscopy; interventional ultrasonography; radiation exposure

Ask authors/readers for more resources

This study compared radiation exposure in endoscopic ultrasound-guided drainage (EUS-D) and endoscopic retrograde cholangiopancreatography drainage (ERCP-D), finding that despite shorter procedure time, EUS-D had significantly higher radiation doses than ERCP-D.
Objectives The transpapillary drainage by endoscopic retrograde cholangiopancreatography (ERCP-D) cannot be performed without fluoroscopy, and there are many situations in which fluoroscopy is required even in endoscopic ultrasound-guided drainage (EUS-D). Previous studies have compared the efficacy, but not the radiation exposure of EUS-D and ERCP-D. While radiation exposure in ERCP-D has been previously evaluated, there is a paucity of information regarding radiation doses in EUS-D. This study aimed to assess radiation exposure in EUS-D compared with that in ERCP-D. Methods This retrospective single-center cohort study included consecutive patients who underwent EUS-D and ERCP-D between October 2017 and March 2019. The air kerma (AK, mGy), kerma-area product (KAP, Gycm(2)), fluoroscopy time (FT, min), and procedure time (PT, min) were assessed. The invasive probability weighting method was used to qualify the comparisons. Results We enrolled 372 and 105 patients who underwent ERCP-D and EUS-D, respectively. The mean AK, KAP, and FT in the EUS-D group were higher by 53%, 28%, and 27%, respectively, than those in the ERCP-D group, whereas PT was shorter by approximately 11% (AK, 135.0 vs. 88.4; KAP, 28.1 vs. 21.9; FT, 20.4 vs. 16.0; PT, 38.7 vs. 43.5). The sub-analysis limited to biliary drainage cases showed the same trend (AK, 128.3 vs. 90.9; KAP, 27.0 vs. 22.2; FT, 16.4 vs. 16.1; PT, 32.5 vs. 44.4). Conclusions This is the first study to assess radiation exposure in EUS-D compared with that in ERCP-D. Radiation exposure was significantly higher in EUS-D than in ERCP-D, despite the shorter procedure time.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available