4.7 Article

Combined influence of forearm orientation and muscular contraction on EMG pattern recognition

Journal

EXPERT SYSTEMS WITH APPLICATIONS
Volume 61, Issue -, Pages 154-161

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.eswa.2016.05.031

Keywords

Accelerometer; EMG; Generalizability; Pattern recognition

Funding

  1. EPSRC, UK [EP/M025977/1, EP/M025594/1]
  2. Engineering and Physical Sciences Research Council [EP/M025977/1, EP/M025594/1] Funding Source: researchfish
  3. EPSRC [EP/M025977/1, EP/M025594/1] Funding Source: UKRI

Ask authors/readers for more resources

The performance of intelligent electromyogram (EMG)-driven prostheses, functioning as artificial alternatives to missing limbs, is influenced by several dynamic factors including: electrode position shift, varying muscle contraction level, forearm orientation, and limb position. The impact of these factors on EMG pattern recognition has been previously studied in isolation, with the combined effect of these factors being understudied. However, it is likely that a combination of these factors influences the accuracy. We investigated the combined effect of two dynamic factors, namely, forearm orientation and muscle contraction levels, on the generalizability of the EMG pattern recognition. A number of recent time- and frequency domain EMG features were utilized to study the EMG classification accuracy. Twelve intact-limbed and one bilateral transradial (below-elbow) amputee subject were recruited. They performed six classes of wrist and hand movements at three muscular contraction levels with three forearm orientations (nine conditions). Results indicate that a classifier trained by features that quantify the angle, rather than amplitude, of the muscle activation patterns perform better than other feature sets across different contraction levels and forearm orientations. In addition, a classifier trained with the EMG signals collected at multiple forearm orientations with medium muscular contractions can generalize well and achieve classification accuracies of up to 91%. Furthermore, inclusion of an accelerometer to monitor wrist movement further improved the EMG classification accuracy. The results indicate that the proposed methodology has the potential to improve robustness of myoelectric pattern recognition. (C) 2016 The Authors. Published by Elsevier Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available