4.5 Article

Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems

Journal

CLINICAL ORAL INVESTIGATIONS
Volume 26, Issue 2, Pages 1283-1291

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00784-021-04102-4

Keywords

CAD; CAM; Dental implant; Fixed partial dentures; Internal fit; Marginal gap

Funding

  1. Research Fund of the Recep Tayyip Erdogan University, Rize, Turkey [TDH-2019-1014]

Ask authors/readers for more resources

This study compared the marginal and internal fit of implant-supported fixed dentures fabricated using CAD/CAM systems. The results showed that all substructures had a marginal and internal fit within acceptable clinical limits.
Objective This study compared the marginal and internal fit of implant-supported fixed dentures fabricated using CAD/CAM systems. Materials and methods A lower jaw model representing partial edentulism was produced. Two dental implants were inserted in the area of teeth 35 and 37, onto which cemented abutments were screwed. The model was scanned using a laboratory scanner and transferred to a design software program for substructure fabrication. Sixty substructures were fabricated out of each group for six substructure types (n = 10), cast Co-Cr (control), milling Co-Cr, laser sintering Co-Cr, titanium (Ti), zirconium, and polyetheretherketone (PEEK) substructures. The marginal and internal fit was evaluated using a silicone replica viewed under a stereomicroscope. The data were analyzed using the statistical package program for social sciences (SPSS, Chicago, IL, USA, v. 17) at a significance level of 0.05. Marginal and internal gaps were compared using the one-way ANOVA test and Tukey's post hoc test. The differences between abutment teeth were determined using the independent sample t-test. Results There was a significant difference in the marginal gap between PEEK and Ti groups (p < 0.05) but no difference between other groups (p > 0.05). There was a significant difference in the internal gap between PEEK, laser sintering Co-Cr, and milling Co-Cr groups (p < 0.05) but no difference between other groups (p > 0.05). The PEEK group had a higher marginal gap than the Ti group and a higher internal gap than the DMLS Co-Cr group (p < 0.05). Conclusion All substructures have a marginal and internal fit within acceptable clinical limits.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available