4.7 Article

Validation of Clinically Relevant Thresholds of Esophagogastric Junction Obstruction Using FLIP Panometry

Journal

CLINICAL GASTROENTEROLOGY AND HEPATOLOGY
Volume 20, Issue 6, Pages E1250-E1262

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.cgh.2021.06.040

Keywords

Dysphagia; Reflux; Impedance

Funding

  1. Public Health Service [P01 DK117824]
  2. American College of Gastroenterology Junior Faculty Development Award

Ask authors/readers for more resources

FLIP panometry accurately identifies clinically relevant esophagogastric junction obstruction as defined by the Chicago Classification version 4.0 in patients evaluated for esophageal motor disorders. It is a valuable tool for assessing esophageal motility.
BACKGROUND & AIMS: This study aimed to assess the accuracy of functional luminal imaging probe (FLIP) panometry to detect esophagogastric junction (EGJ) obstruction assigned by high-resolution manometry (HRM) and the Chicago Classification version 4.0 (CCv4.0). METHODS: Six hundred eighty-seven adult patients who completed FLIP and HRM for primary esophageal motility evaluation and 35 asymptomatic volunteers (controls) were included. EGJ opening was evaluated with 16-cm FLIP during sedated endoscopy via EGJ-distensibility index (DI) and maximum EGJ diameter. HRM was classified according to CCv4.0 and focused on studies with a conclusive disorder of EGJ outflow (ie, achalasia subtypes I, II, or III; or EGJ outflow obstruction with abnormal timed barium esophagogram) or normal EGJ outflow. RESULTS: All 35 controls had EGJ-DI >3.0 mm(2)/mmHg and maximum EGJ diameter >16 mm. Per HRM and CCv4.0, 245 patients had a conclusive disorder of EGJ outflow, and 314 patients had normal EGJ outflow. Among the 241 patients with reduced EGJ opening (EGJ-DI <2.0 mm(2)/mmHg and maximum EGJ diameter <12 mm) on FLIP panometry, 86% had a conclusive disorder of EGJ outflow per CCv4.0. Among the 203 patients with normal EGJ opening (EGJ-DI >= 2.0 mm(2)/mmHg and maximum EGJ diameter >= 16 mm) on FLIP panometry, 99% had normal EGJ outflow per CCv4.0. CONCLUSIONS: FLIP panometry accurately identified clinically relevant conclusive EGJ obstruction as defined by CCv4.0 in patients evaluated for esophageal motor disorders. Thus, FLIP panometry is a valuable tool for both independent and complementary evaluation of esophageal motility.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended