Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With High Power-Short Duration and Moderate Power-Moderate Duration: Effects of Thermal Latency and Contact Force on Lesion Formation

Journal

CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY
Volume 14, Issue 7, Pages 605-617

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCEP.121.009899

Keywords

atrial fibrillation; catheter ablation; radiofrequency current; tachycardia; ventricular; thrombosis

Funding

  1. Biosense Webster, Inc.

Ask authors/readers for more resources

This study compared tissue temperature profiles, lesion sizes, and complications between different RF ablation parameters. The results showed that RF ablation with very high power and short duration (90W/4s) resulted in the smallest tissue temperatures and lesion sizes, while ablation with moderate power and longer duration (30W/30s) led to the largest outcomes. Additionally, RF applications at 90W/4s exhibited a longer thermal latency, indicating a significant portion of the lesion was created after RF termination.
Background: With short radiofrequency (RF) applications, tissue temperature continues to rise after RF termination (thermal latency), which may result in lesion growth after RF termination. The purpose was to compare in vivo tissue temperature profile (thermal latency), lesion size, and the incidence of steam pop and thrombus between RF ablation with very high power-very short RF (90 W/4 s), high power-short RF (50 W/10 s), and moderate power-moderate RF (30 W/30 s) in a canine thigh muscle preparation and beating heart. Methods: In the thigh muscle preparation (5 dogs), a 3.5-mm ablation electrode with 66 or 56 small irrigation holes (QDOT-Micro or ThermoCoolSmartTouch-SF, respectively) was held perpendicular or parallel to the muscle at 10g or 30g contact force. Total of 120 RFs were delivered at 90 W/4 s (QDOT catheter), 50 W/10 s, or 30 W/30 s (SF catheter). Electrode temperature, electrode-tissue interface temperature, and tissue temperatures at 3- and 7-mm depths were measured. In 6 closed-chest dogs, total of 72 RFs were delivered in the ventricle at 90 W/4 s, 50 W/10 s, or 30 W/30 s. Results: In the thigh muscle preparation, tissue temperatures and lesion size (depth, diameter, and volume) were the lowest/smallest for RFs at 90 W/4 s, followed by 50 W/10 s, and the greatest for 30 W/30 s. Thermal latency (Delta temperature and duration) was the greatest for RFs at 90 W/4 s, followed by 50 W/10 s, and the smallest for 30 W/30 s (P<0.01). Effective tissue heating (area under the curve >= 50 degrees C at 3-mm depth) was observed after RF termination in 88.0 +/- 7.6% with 90 W/4 s, 57.7 +/- 14.6% with 50 W/10 s, and only 31.9 +/- 8.5% with 30 W/30 s (P<0.01). In beating hearts, lesion size was also the smallest with 90 W/4 s and the greatest with 30 W/30 s RFs. Increasing contact force significantly increased lesion depth in all 3 groups. There was no significant difference in the incidence of steam pop or thrombus between 3 groups. Conclusions: Tissue temperatures and lesion size (depth, diameter, and volume) were the lowest/smallest for RF applications at 90 W/4 s, followed by 50 W/10 s, and the greatest for 30 W/30 s. The greater thermal latency for 90 W/4 s RF applications suggests that a significant portion of lesion is created after RF termination due to conductive tissue heating.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available