4.4 Article

Rare-earth Doped Nanoparticles with Narrow NIR-II Emission for Optical Imaging with Reduced Autofluorescence

Journal

CHEMICAL RESEARCH IN CHINESE UNIVERSITIES
Volume 37, Issue 4, Pages 943-950

Publisher

HIGHER EDUCATION PRESS
DOI: 10.1007/s40242-021-1172-9

Keywords

Second near-infrared; Rare-earth; Downconversion nanoparticle; Autofluorescence; Fluorescence imaging

Funding

  1. National Natural Science Foundation of China [21975131, 21674048]
  2. Fund of Synergetic Innovation Center for Organic Electronics and Information Displays
  3. Primary Research & Development Plan of Jiangsu Province, China [BE2016770]

Ask authors/readers for more resources

Fluorescence imaging in the second near-infrared region (NIR-II) has high resolution and penetration depth. Developments in fluorophores with emission bands covering the long-wavelength end of NIR-II region or with narrow bandwidth can reduce autofluorescence. Rare-earth doped nanoparticles with sharp emission show promise in reducing interference signals for imaging in living organisms.
Fluorescence imaging in the second near-infrared region(900-1700 nm, NIR-II) with a high resolution and penetration depth due to the significantly reduced tissue scattering and autofluorescence has emerged as a useful tool in biomedical fields. Recently, many efforts have been devoted to the development of fluorophores with an emission band covering the long-wavelength end of NIR-II region(1500-1700 nm) to eliminate the autofluorescence. Alternatively, we believe imaging with a narrow bandwidth could also reduce the autofluorescence. As a proof of concept, NaYF4:Yb, Nd@NaYF4 downconversion nanoparticles(DCNPs) with sharp NIR-II emission were synthesized. The luminescence of DCNPs showed a half-peak width of 49 nm centered at 998 nm, which was perfectly matched with a (1000 +/- 25) nm bandpass filter. With this filter, we were able to retain most of the emissions from the nanoparticles, while the autofluorescence was largely reduced. After PEGylation, the DCNPs exhibited great performance for blood vessel and tumor imaging in living mice with significantly reduced autofluorescence and interference signals. This work provided an alternative way for the low-autofluorescence imaging and emphasized the importance of narrow emitting rare-earth doped nanoparticles for NIR-II imaging.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available