4.8 Article

Novel SeS2-loaded Co MOF with Au@PANI comprised electroanalytical molecularly imprinted polymer-based disposable sensor for patulin mycotoxin

Journal

BIOSENSORS & BIOELECTRONICS
Volume 187, Issue -, Pages -

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2021.113302

Keywords

Molecularly imprinted polymer; Density functional theory; SeS2-Loaded Co MOF; Patulin; Mycotoxin

Funding

  1. National Research Foundation ofKorea (NRF) [NRF-2020M3A9E410438511]
  2. Gachon University [20190326]
  3. SRM Institute of Science and Technology

Ask authors/readers for more resources

A sensor for detecting PT molecules was developed using electropolymerized molecularly imprinted polymer as the base matrix of the electrode, achieving higher sensitivity and stability.
An SeS2-loaded Co MOF and Au@PANI nanocomposite comprising the base matrix of the electrode was developed with electropolymerized molecularly imprinted polymer (MIP) consisting of p-aminobenzoic acid (PABA) and patulin (PT) to detect PT molecules based on the PT imprinted cavities. SeS2@Co MOF and Au@PANI were synthesized using hydrothermal synthesis and interfacial polymerization strategies, respectively. A suitable functional monomer to fabricate the MIP platform was selected using the density functional theory (DFT/M06-2X method). Higher electrochemical active surface area (0.985 cm2 which is 6.99 times higher than the bare SPE) and a lower charge transfer resistance (Rct = 27.8 LI) at the MIP/Au@PANI/SeS2@Co MOF electrode was achieved based on the higher number of adsorptive sites and enhanced conductivity (electron transfer rate constant (ks = 3.24 x 10-3 s- 1) of the sensing platform. The fabricated MIP sensor performance was studied in 10 mM PBS (pH = 6.4), where an improved detection limit (0.66 pM) for PT and a broad logarithmic linear dynamic range (0.001-100 nM) were both observed. The sensor possessed higher selectivity (Imprinting factor = 15.4 for PT), excellent reusability (%RSD of 10 cycles = 2.49%), high storage stability (6.7% lost after 35 days), and robust reproducibility (%RSD = 3.22%) The as-prepared MIP-based PT sensor was applied to detect PT in a real-time apple juice sample (10% diluted with PBS) with a recovery % ranging from 94.5 to 106.4%. The proposed sensor possesses great advantages in terms of cost-effectiveness, providing a simple detection strategy for longterm storage stability, and reversible cycle measurements.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available