4.6 Article

A multi-type features fusion neural network for blood pressure prediction based on photoplethysmography

Related references

Note: Only part of the references are listed.
Article Computer Science, Hardware & Architecture

Predicting Systolic Blood Pressure in Real-Time Using Streaming Data and Deep Learning

Hager Saleh et al.

Summary: This paper introduces a system that can predict systolic blood pressure in real-time, using deep learning models and real-time data to prevent health problems caused by high blood pressure.

MOBILE NETWORKS & APPLICATIONS (2021)

Article Engineering, Biomedical

Towards accurate estimation of cuffless and continuous blood pressure using multi-order derivative and multivariate photoplethysmogram features

Wan-Hua Lin et al.

Summary: This study investigated the efficiency and accuracy of using only PPG features for CC-BP estimation, demonstrating that using 65 PPG features resulted in significantly higher accuracy compared to using hybrid PAT and PPG indicators.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2021)

Article Chemistry, Analytical

Beat-to-Beat Continuous Blood Pressure Estimation Using Bidirectional Long Short-Term Memory Network

Dongseok Lee et al.

Summary: A cuffless blood pressure estimation model using deep learning algorithms was proposed, with features extracted from electrocardiogram, photoplethysmogram, and ballistocardiogram. The model achieved high accuracy in both one-day and multi-day tests, showing its potential for continuous blood pressure monitoring for patients with hypertension.

SENSORS (2021)

Review Engineering, Biomedical

A review of machine learning techniques in photoplethysmography for the non-invasive cuff-less measurement of blood pressure

C. El-Hajj et al.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2020)

Article Biology

A multistage deep neural network model for blood pressure estimation using photoplethysmogram signals

Jamal Esmaelpoor et al.

COMPUTERS IN BIOLOGY AND MEDICINE (2020)

Article Computer Science, Artificial Intelligence

Continuous blood pressure measurement from one-channel electrocardiogram signal using deep-learning techniques

Fen Miao et al.

ARTIFICIAL INTELLIGENCE IN MEDICINE (2020)

Article Computer Science, Artificial Intelligence

Multi-level information fusion for learning a blood pressure predictive model using sensor data

Monika Simjanoska et al.

INFORMATION FUSION (2020)

Article Engineering, Biomedical

Cuff-less continuous measurement of blood pressure using wrist and fingertip photo-plethysmograms: Evaluation and feature analysis

Ahmadreza Attarpour et al.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2019)

Review Health Care Sciences & Services

The use of photoplethysmography for assessing hypertension

Mohamed Elgendi et al.

NPJ DIGITAL MEDICINE (2019)

Review Computer Science, Interdisciplinary Applications

Deep learning for healthcare applications based on physiological signals: A review

Oliver Faust et al.

COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE (2018)

Article Computer Science, Artificial Intelligence

Optimal approximation of piecewise smooth functions using deep ReLU neural networks

Philipp Petersen et al.

NEURAL NETWORKS (2018)

Article Mathematical & Computational Biology

Continuous Cuff-Less Blood Pressure Estimation Based on Combined Information Using Deep Learning Approach

Dan Wu et al.

JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS (2018)

Article Computer Science, Information Systems

Multiscaled Fusion o Deep Convolutional Neural Networks for Screening Atrial Fibrillation From Single Lead Short ECG Recordings

Xiaomao Fan et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2018)

Article Engineering, Biomedical

Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring

Mohammad Kachuee et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2017)

Article Automation & Control Systems

Oscillometric Blood Pressure Estimation Based on Deep Learning

Soojeong Lee et al.

IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS (2017)

Article Computer Science, Information Systems

Deep Belief Networks Ensemble for Blood Pressure Estimation

Soojeong Lee et al.

IEEE ACCESS (2017)

Article Computer Science, Hardware & Architecture

Noninvasive cuffless blood pressure estimation using pulse transit time and Hilbert-Huang transform

Younhee Choi et al.

COMPUTERS & ELECTRICAL ENGINEERING (2013)

Article Cardiac & Cardiovascular Systems

On the Analysis of Fingertip Photoplethysmogram Signals

Mohamed Elgendi

CURRENT CARDIOLOGY REVIEWS (2012)

Article Cardiac & Cardiovascular Systems

Frequency-dependent baroreflex modulation of blood pressure and heart rate variability in conscious mice

R Fazan et al.

AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY (2005)

Review Physiology

Arterial baroreflex function and cardiovascular variability: interactions and implications

PA Lanfranchi et al.

AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY (2002)