4.4 Article

Speciation of As(III) and As(V) in Food by Magnetic Dispersive Microsolid Phase Extraction with Dispersive Liquid-Liquid Microextraction with Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Detection

Journal

ANALYTICAL LETTERS
Volume 55, Issue 2, Pages 269-280

Publisher

TAYLOR & FRANCIS INC
DOI: 10.1080/00032719.2021.1925290

Keywords

Arsenic speciation; dairy products; dispersive liquid-liquid microextraction (DLLME); graphite furnace atomic absorption spectrometry (GFAAS); magnetic dispersive microsolid phase extraction (MDMSPE)

Funding

  1. Nature Science Foundation of Hubei Province [2019CFB159]
  2. Research and Innovation Initiatives of Wuhan Polytechnic University [2018J04, 2018Y07]

Ask authors/readers for more resources

The combination of MDMSPE and DLLME was utilized for the separation and preconcentration of arsenic(III) and arsenic(V), showing good recoveries and analytical results in dairy products analysis.
Magnetic dispersive microsolid phase extraction (MDMSPE) was coupled with dispersive liquid-liquid microextraction (DLLME) for the separation and preconcentration of arsenic(V) and arsenic(III) prior to graphite furnace atomic absorption spectrometry detection. In the first step, magnetic ZnFe2O4 nanotubes were employed for adsorbing arsenic(V). The adsorbent was separated from the aqueous phase by the use of an external magnetic field. Next, arsenic(III) in the upper aqueous phase from MDMSPE was enriched by DLLME. Samples were prepared with artificial gastric juice to avoid inter-conversion of the determined species. The parameters affecting the separation and preconcentration of the determined species were optimized. The detection limits of this protocol were determined to be 1.3 and 2.0 pg mL(-)(1) for arsenic(III) and arsenic(V) with relative standard deviations of 4.5% and 5.6% for a concentration of 1.0 ng mL(-)(1) (n = 9). The enrichment factors were equal to 175-fold for arsenic(III) and 163-fold for arsenic(V). The developed protocol was employed for the determination of arsenic(III) and arsenic(V) in dairy products without preoxidation or prereduction. The recoveries of spiked samples were from 90.8% to 105%. A milk powder certified reference material was analyzed by this approach and the measured results were in good agreement with the certified value.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available