4.8 Article

Screening and Identification of Epoxy/Dihydroxy-Oxylipins by Chemical Labeling-Assisted Ultrahigh-Performance Liquid Chromatography Coupled with High-Resolution Mass Spectrometry

Journal

ANALYTICAL CHEMISTRY
Volume 93, Issue 28, Pages 9904-9911

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c02058

Keywords

-

Funding

  1. National Key Research and Development Program of China [2018YFA0900400]
  2. National Natural Science Foundation of China [21635006, 21721005, 21904099]

Ask authors/readers for more resources

In this study, a highly sensitive and specific method for screening and annotating epoxy/dihydroxy-oxylipins in biological samples was established using chemical labeling-assisted liquid chromatography coupled with high-resolution mass spectrometry. The analysis revealed the presence of potential epoxy/dihydroxy-oxylipins, including previously unreported compounds, in human serum and high-fat diet mouse heart samples. Moreover, the method showed a significant decrease in the levels of certain epoxy/dihydroxy-oxylipins in the heart of mice with high-fat diet, particularly those derived from linoleic acid or alpha-linolenic acid.
Epoxy/dihydroxy-oxylipins are important biologically active compounds that are mainly formed from polyunsaturated fatty acids (PUFAs) in the reactions catalyzed by the cytochrome P450 (CYP 450) enzyme. The analysis of epoxy/dihydroxy-oxylipins would be helpful to gain insights into their landscape in living organisms and provide a reference for the biological studies of these compounds. In this work, we employed chemical labeling-assisted liquid chromatography (LC) coupled with high-resolution mass spectrometry (CL-LC-HRMS) to establish a highly sensitive and specific method for screening and annotating epoxy/dihydroxy-oxylipins in biological samples. The isotope reagents 2-dimethylaminoethylamine (DMED) and DMED-d(4) were employed to label epoxy/dihydroxy-oxylipins containing carboxyl groups so as to improve the analysis selectivity and MS detection sensitivity of epoxy/dihydroxy-oxylipins. Based on a pair of diagnostic ions with a mass-to-charge ratio (m/z) difference of 15.995 originating from the fragmentation of derivatives via high-energy collision dissociation (HCD), the potential epoxy/dihydroxy-oxylipins were rapidly screened from the complex matrix. Furthermore, the epoxy/dihydroxy groups could be readily localized by the diagnostic ion pairs, which enabled us to accurately annotate the epoxy/dihydroxy-oxyiipins detected in biological samples. The applicability of our method was demonstrated by profiling epoxy/dihydroxy-oxylipins in human serum and heart samples from mice with high-fat diet (HFD). By the proposed method, a total of 32 and 62 potential epoxy/dihydroxyoxylipins including 42 unreported ones were detected from human serum and the mice heart sample, respectively. Moreover, the relative quantitative results showed that most of the potential epoxy/dihydroxy-oxylipins, especially the oxidation products of linoleic acid (LA) or alpha-linolenic acid (ALA), were significantly decreased in the heart of mice with HFD. Our developed method is of high specificity and sensitivity and thus is a promising tool for the identification of novel epoxy/dihydroxy-oxylipins in biological samples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available