4.2 Article

Influence of calcium ion-modified implant surfaces in protein adsorption and implant integration

Journal

Publisher

SPRINGER JAPAN KK
DOI: 10.1186/s40729-021-00314-1

Keywords

Titanium implants; Osseointegration; Blood coagulation; Implant surface design; Protein adsorption

Funding

  1. Universitat Jaume I [POSDOC/2019/28]
  2. Generalitat Valenciana [GRISOLIAP/2018/091]
  3. University of the Basque Country [UFI11/56]
  4. Basque Government [PRE_2017_2_0044]
  5. Basque Department of Industry, Tourism and Trade (Etortek program)
  6. Basque Department of Industry, Tourism and Trade (Elkartek program)
  7. Innovation Technology Department of the Bizkaia County
  8. ProteoRed-ISCIII [PRB3 IPT17/0019]
  9. CIBERehd Network
  10. Severo Ochoa Grant [SEV-2016-0644]

Ask authors/readers for more resources

This study investigated the difference in protein adsorption pattern and in vivo responses between surfaces modified with calcium ions and standard titanium implant surfaces, revealing a stronger thrombogenic protein adsorption pattern on calcium ion surfaces correlated with higher levels of implant osseointegration. Therefore, more effective implant surfaces may help reduce invasive surgeries, shorten healing times, and lower intervention costs.
Background Calcium (Ca) is a well-known element in bone metabolism and blood coagulation. Here, we investigate the link between the protein adsorption pattern and the in vivo responses of surfaces modified with calcium ions (Ca-ion) as compared to standard titanium implant surfaces (control). We used LC-MS/MS to identify the proteins adhered to the surfaces after incubation with human serum and performed bilateral surgeries in the medial section of the femoral condyles of 18 New Zealand white rabbits to test osseointegration at 2 and 8 weeks post-implantation (n=9). Results Ca-ion surfaces adsorbed 181.42 times more FA10 and 3.85 times less FA12 (p<0.001), which are factors of the common and the intrinsic coagulation pathways respectively. We also detected differences in A1AT, PLMN, FA12, KNG1, HEP2, LYSC, PIP, SAMP, VTNC, SAA4, and CFAH (p<0.01). At 2 and 8 weeks post-implantation, the mean bone implant contact (BIC) with Ca-ion surfaces was respectively 1.52 and 1.25 times higher, and the mean bone volume density (BVD) was respectively 1.35 and 1.13 times higher. Differences were statistically significant for BIC at 2 and 8 weeks and for BVD at 2 weeks (p<0.05). Conclusions The strong thrombogenic protein adsorption pattern at Ca-ion surfaces correlated with significantly higher levels of implant osseointegration. More effective implant surfaces combined with smaller implants enable less invasive surgeries, shorter healing times, and overall lower intervention costs, especially in cases of low quantity or quality of bone.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available