4.7 Article

e Software performance in segmenting ground-glass and solid components of subsolid nodules in pulmonary adenocarcinomas

Journal

EUROPEAN RADIOLOGY
Volume 26, Issue 12, Pages 4465-4474

Publisher

SPRINGER
DOI: 10.1007/s00330-016-4317-3

Keywords

Solitary pulmonary nodule; Lung cancer; Subsolid nodule; Adenocarcinoma; Segmentation

Funding

  1. National RAMP
  2. D Program for Cancer Control, Ministry for Health and Welfare, Republic of Korea [1520230]
  3. Societe Francaise de Radiologie (SFR)
  4. College des Enseignants de Radiologie de France (CERF)

Ask authors/readers for more resources

To evaluate the performance of software in segmenting ground-glass and solid components of subsolid nodules in pulmonary adenocarcinomas. Seventy-three pulmonary adenocarcinomas manifesting as subsolid nodules were included. Two radiologists measured the maximal axial diameter of the ground-glass components on lung windows and that of the solid components on lung and mediastinal windows. Nodules were segmented using software by applying five (-850 HU to -650 HU) and nine (-130 HU to -500 HU) attenuation thresholds. We compared the manual and software measurements of ground-glass and solid components with pathology measurements of tumour and invasive components. Segmentation of ground-glass components at a threshold of -750 HU yielded mean differences of +0.06 mm (p = 0.83, 95 % limits of agreement, 4.51 to 4.67) and -2.32 mm (p < 0.001, -8.27 to 3.63) when compared with pathology and manual measurements, respectively. For solid components, mean differences between the software (at -350 HU) and pathology measurements and between the manual (lung and mediastinal windows) and pathology measurements were -0.12 mm (p = 0.74, -5.73 to 5.55]), 0.15 mm (p = 0.73, -6.92 to 7.22), and -1.14 mm (p < 0.001, -7.93 to 5.64), respectively. Software segmentation of ground-glass and solid components in subsolid nodules showed no significant difference with pathology. aEuro cent Software can effectively segment ground-glass and solid components in subsolid nodules. aEuro cent Software measurements show no significant difference with pathology measurements. aEuro cent Manual measurements are more accurate on lung windows than on mediastinal windows.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available