4.6 Article

Focal Vibration Therapy: Vibration Parameters of Effective Wearable Devices

Journal

APPLIED SCIENCES-BASEL
Volume 11, Issue 7, Pages -

Publisher

MDPI
DOI: 10.3390/app11072969

Keywords

focal vibration therapy; vibration frequency; vibration amplitude; vibration intensity

Funding

  1. Oklahoma Center for the Advancement of Science and Technology (OCAST) Health Research [HR18-034]

Ask authors/readers for more resources

This study evaluated the vibration characteristics of four commercially available focal vibration devices and identified effective ranges of focal vibration frequency and amplitude. The results highlight the importance of considering the vibration environment when quoting vibration characteristics. Additionally, the inconsistency output of multi-actuator devices was discussed, providing guidance for protocol development and potential improvements for focal vibration devices.
Focal vibration therapy can provide neurophysiological benefits. Unfortunately, standardized protocols are non-existent. Previous research presents a wide range of protocols with a wide range of effectiveness. This paper is part of a broader effort to identify effective, standardized protocols for focal vibration therapy. In this study, the authors evaluated the vibration characteristics (frequency and peak-to-peak intensity) of four commercially available focal vibration devices: (1) Vibracool (wearable), (2) Novafon (hand-held), (3) Myovolt 3-actuator (wearable), and (4) Myovolt 2-actuator (wearable). An accelerometer was used for the measurements. Measurements were made under the following two conditions: (a) when the devices were free, i.e., unconstrained vibration, and (b) when the devices were strapped to the human body, i.e., constrained vibration. In the free vibration condition, frequency ranged from 120 to 225 Hz and peak-to-peak amplitude ranged from 2.0 to 7.9 g's. When the devices were strapped to the body (constrained), vibration amplitude decreased by up to 65.7%. These results identify effective ranges of focal vibration frequency and amplitude. They illustrate the importance of identifying vibration environment, free or constrained, when quoting vibration characteristics. Finally, the inconsistency output of multi-actuator devices is discussed. These results will guide protocol development for focal vibration and potentially better focal vibration devices.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available