4.7 Article

Diagnostic performance and characteristics of anterior nasal collection for the SARS-CoV-2 antigen test: a prospective study

Related references

Note: Only part of the references are listed.
Article Infectious Diseases

Clinical validation of quantitative SARS-CoV-2 antigen assays to estimate SARS-CoV-2 viral loads in nasopharyngeal swabs

Kotaro Aoki et al.

Summary: The study found that Lumipulse (R) SARS-CoV-2 Ag has high concordance with RT-PCR for SARS-CoV-2 and can be used for the diagnosis of COVID-19 in any clinical setting. Therefore, this fully automated chemiluminescent enzyme immunoassay system will contribute to the expansion of testing capability for SARS-CoV-2.

JOURNAL OF INFECTION AND CHEMOTHERAPY (2021)

Article Infectious Diseases

Multicenter evaluation of the Panbio™ COVID-19 rapid antigen-detection test for the diagnosis of SARS-CoV-2 infection

Paloma Merino et al.

Summary: The study aimed to evaluate the performance of the PanbioRT COVID-19 Ag Rapid Test Device in detecting SARS-CoV-2 in patients with COVID-19 symptoms. The results showed that PanbioRT performed well clinically, especially for patients with a shorter clinical course or a higher viral load.

CLINICAL MICROBIOLOGY AND INFECTION (2021)

Article Infectious Diseases

The evaluation of a newly developed antigen test (QuickNaviTM-COVID19 Ag) for SARS-CoV-2: A prospective observational study in Japan

Yuto Takeuchi et al.

Summary: In this study, the newly developed QuickNaviTM-COVID19 Ag antigen test in Japan showed high specificity and sufficient sensitivity for detecting SARS-CoV-2. The test performed well, especially in symptomatic patients.

JOURNAL OF INFECTION AND CHEMOTHERAPY (2021)

Article Infectious Diseases

Prospective study of 1308 nasopharyngeal swabs from 1033 patients using the LUMIPULSE SARS-CoV-2 antigen test: Comparison with RT-qPCR

Yosuke Hirotsu et al.

Summary: This prospective study demonstrated that the LUMIPULSE antigen test is highly accurate for SARS-CoV-2 detection, showing high sensitivity and specificity, particularly in diagnosing the disease accurately in the late phase of infection.

INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES (2021)

Review Infectious Diseases

Diagnostic performance of different sampling approaches for SARS-CoV-2 RT-PCR testing: a systematic review and meta-analysis

Nicole Ngai Yung Tsang et al.

Summary: This study systematically compared the diagnostic performance of different clinical specimen collection methods for SARS-CoV-2 infection. Pooled nasal and throat swabs showed the highest sensitivity and positive predictive value, while saliva and nasal swabs also demonstrated good diagnostic performance. Throat swabs had a significantly lower sensitivity and positive predictive value and were not recommended for diagnosis. Self-collection for pooled nasal and throat swabs and nasal swabs did not affect diagnostic accuracy.

LANCET INFECTIOUS DISEASES (2021)

Article Medicine, General & Internal

Clinical assessment of the Roche SARS-CoV-2 rapid antigen test

Gian Luca Salvagno et al.

Summary: The study assessed the clinical performance of the Roche SARS-CoV-2 Rapid Antigen Test and found that it has excellent accuracy and sensitivity in nasopharyngeal swabs with Ct values <25, making it reliable for screening patients with high viral load. However, more sensitive techniques would be needed for mass community screening.

DIAGNOSIS (2021)

Letter Microbiology

Nasal Swab Sampling for SARS-CoV-2: a Convenient Alternative in Times of Nasopharyngeal Swab Shortage

Helene Pere et al.

JOURNAL OF CLINICAL MICROBIOLOGY (2020)

Article Biotechnology & Applied Microbiology

The influence of a swab type on the results of point-of-care tests

Aleksandra Anna Zasada et al.

AMB EXPRESS (2020)

Editorial Material Medicine, General & Internal

How to Obtain a Nasopharyngeal Swab Specimen

Francisco M. Marty et al.

NEW ENGLAND JOURNAL OF MEDICINE (2020)

Article Infectious Diseases

Development of Genetic Diagnostic Methods for Detection for Novel Coronavirus 2019(nCoV-2019) in Japan

Kazuya Shirato et al.

JAPANESE JOURNAL OF INFECTIOUS DISEASES (2020)

Letter Medicine, General & Internal

Swabs Collected by Patients or Health Care Workers for SARS-CoV-2 Testing

Yuan-Po Tu et al.

NEW ENGLAND JOURNAL OF MEDICINE (2020)

Letter Virology

Another false-positive problem for a SARS-CoV-2 antigen test in Japan

Taku Ogawa et al.

JOURNAL OF CLINICAL VIROLOGY (2020)

Article Medicine, Legal

The Extraction and Recovery Efficiency of Pure DNA for Different Types of Swabs

Brigitte B. Bruijns et al.

JOURNAL OF FORENSIC SCIENCES (2018)