4.6 Article

Does the Modification of the Apical Geometry of a Dental Implant Affect Its Primary Stability? A Comparative Ex Vivo Study

Journal

MATERIALS
Volume 14, Issue 7, Pages -

Publisher

MDPI
DOI: 10.3390/ma14071728

Keywords

dental implant primary stability; camlog screw-line promote(®); plus; apical screw thread; bone density; J-line; K-line

Ask authors/readers for more resources

The study found that primary stability of dental implants increases with increasing length and the presence of screw threads at the apical end in both hard and soft bone. Undersized drilling preparation in soft bone significantly improves primary stability.
(1) Background: Primary stability-one fundamental criterion for the success of dental implants-is influenced by implant geometry even if the effect of apical shape modifications on implant primary stability has not yet been examined. Therefore, the aim of the ex vivo study was to compare primary stability of implants differing in apically located screw threads (J-line) or a flat tip (K-line) only. (2) Methods: 28 implants of each group of the same diameter (4.3 mm) were randomly inserted into porcine bone blocks. The first group (9, 11 and 13 mm) was inserted into hard, the second (11 mm) into soft bone, here using a normal and an undersized drilling protocol. Insertion torque (Ncm), Periotest(R) value, resonance frequency (implant stability coefficient, ISQ) and push-out force (N) were measured. (3) Results: In hard bone, primary stability increased with increasing length in both groups but it was significantly higher in J-line (p < 0.03). An undersized preparation of the implant bed in soft bone resulted in a significant increase in primary stability in both groups. Here, J-line also showed a significantly increased primary stability when compared to equally prepared K-line (insertion torque: 37 Ncm vs. 26 Ncm; Periotest(R): -6.5 vs. -4.3; push-out force: 365 N vs. 329 N; p < 0.05 each). (4) Conclusions: Primary stability is significantly higher with increasing implant length and apically located screw threads as well as with undersized drilling protocols. When preparing the implant site and subsequently selecting the implant system, modifying factors such as implant geometry (also at the tip) should be taken into account.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available