4.5 Article

Role of echocardiography in uncomplicated Staphylococcus aureus catheter-related bloodstream infections

Journal

MEDICINE
Volume 100, Issue 18, Pages -

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MD.0000000000025679

Keywords

catheter-related bloodstream infection; echocardiography; Staphylococcus aureus; uncomplicated bacteremia

Ask authors/readers for more resources

This study found that in patients with uncomplicated S. aureus CRBSI, the risk of treatment failure may be more influenced by factors such as liver cirrhosis and other prostheses, rather than the implementation of echocardiography. Routine echocardiography might not be necessary given the low rates of adverse outcomes observed, and could be considered on an individual basis.
Uncomplicated bacteremia and catheter-related bloodstream infection (CRBSI) are frequently suggested as factors associated with low risk of infective endocarditis in Staphylococcus aureus bacteremia (SAB). Nevertheless, guidelines recommend that echocardiography in all patients with SAB. We evaluated the effects of echocardiography on patient outcomes. Patients with uncomplicated S. aureus CRBSI were retrospectively identified between January 2013 and June 2018 at a 1950-bed, tertiary-care university hospital. Treatment failure was defined as any case of relapse or all-cause death within 90 days. Of 890 SAB patients, 95 with uncomplicated S. aureus CRBSI were included. Thirty-two patients underwent echocardiography within 30 days of their first positive blood culture. Two patients who underwent echocardiography revealed right-sided infective endocarditis. One patient who did not undergo echocardiography experienced recurrent SAB (peripheral CRBSI) 85 days after his first positive blood culture. There were no SAB-related deaths. The Kaplan-Meier curves of treatment failure showed no significant differences between patients who did and did not undergo echocardiography (P = .77). In multivariable analysis, risk factors for treatment failure were liver cirrhosis (hazard ratio: 9.60; 95% confidence interval: 2.13-43.33; P = .003) and other prostheses (hazard ratio: 63.79; 95% confidence interval: 5.05-805.40; P = .001). This study did not verify the putative association between treatment failure and implementation of echocardiography in patients with uncomplicated S. aureus CRBSI. Given the low observed rates of adverse outcomes, routine echocardiography might not be obligatory and could be performed on an individual basis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available