4.5 Article

A self-decoupled 32-channel receive array for human-brain MRI at 10.5 T

Journal

MAGNETIC RESONANCE IN MEDICINE
Volume 86, Issue 3, Pages 1759-1772

Publisher

WILEY
DOI: 10.1002/mrm.28788

Keywords

noise correlation; parallel imaging; receive array; RF coils; self-decoupling; ultrahigh-field MRI

Funding

  1. National Institutes of Health [U01EB025144, P41 EB027061, NIH S10 RR029672, P30 NS076408, NIH R34AG055178]

Ask authors/readers for more resources

Comparative study of 32-channel receive arrays at 7T and 10.5T revealed that the 10.5T-32Rx provides higher SNR, enhanced parallel-imaging performance, and a greater minimum inverse g-factor value compared to the 7T-32Rx.
Purpose: Receive array layout, noise mitigation, and B-0 field strength are crucial contributors to SNR and parallel-imaging performance. Here, we investigate SNR and parallel-imaging gains at 10.5 T compared with 7 T using 32-channel receive arrays at both fields. Methods: A self-decoupled 32-channel receive array for human brain imaging at 10.5 T (10.5T-32Rx), consisting of 31 loops and one cloverleaf element, was co-designed and built in tandem with a 16-channel dual-row loop transmitter. Novel receive array design and self-decoupling techniques were implemented. Parallel imaging performance, in terms of SNR and noise amplification (g-factor), of the 10.5T-32Rx was compared with the performance of an industry-standard 32-channel receiver at 7 T (7T-32Rx) through experimental phantom measurements. Results: Compared with the 7T-32Rx, the 10.5T-32Rx provided 1.46 times the central SNR and 2.08 times the peripheral SNR. Minimum inverse g-factor value of the 10.5T-32Rx (min[1/g] = 0.56) was 51% higher than that of the 7T-32Rx (min[1/g] = 0.37) with R = 4 x 4 2D acceleration, resulting in significantly enhanced parallel-imaging performance at 10.5 T compared with 7 T. The g-factor values of 10.5 T-32 Rx were on par with those of a 64-channel receiver at 7 T (eg, 1.8 vs 1.9, respectively, with R = 4 x 4 axial acceleration). Conclusion: Experimental measurements demonstrated effective self-decoupling of the receive array as well as substantial gains in SNR and parallel-imaging performance at 10.5 T compared with 7 T.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available