4.3 Article

Gradual-radius femoral component with s-curve post-cam provides stable kinematics at mid-flexion after total knee arthroplasty

Journal

JOURNAL OF ORTHOPAEDIC SCIENCE
Volume 27, Issue 3, Pages 665-671

Publisher

ELSEVIER
DOI: 10.1016/j.jos.2021.02.015

Keywords

-

Categories

Ask authors/readers for more resources

The study evaluated knee kinematics and clinical outcomes of a novel TKA design to prevent mid-flexion instability after surgery. Results showed that the design provided stable kinematics and favorable clinical results during dynamic movements, with significant improvements in patient-reported outcomes.
Background: Mid-flexion instability is the one of the reasons for patient dissatisfaction after total knee arthroplasty (TKA). The purposes of this study were to evaluate in vivo knee kinematics and clinical outcomes using a novel TKA design with a gradual femoral radius component and s-curve post-cam, which are intended to prevent the instability initiated by sudden reductions in the femoral radius observed with conventional components.Methods: We used radiographic-based, image-matching techniques to analyze femorotibial anteroposterior translation, axial rotation, and anterior/posterior cam-post contact during two dynamic movements, squatting and stair climbing, in 20 knees that had undergone posterior-stabilized fixed bearing TKA with an improved sagittal profiles of the femoral component and post-cam mechanism. We also evaluated patient-reported outcomes assessed by the 2011 Knee Society Score (KSS 2011).Results: Squatting and stair climbing produced a similar trend in anteroposterior translation and a relatively small standard deviation at mid-flexion. Although the rotation angles varied widely during squatting and stair climbing, the femoral component was consistently externally rotated. Anterior/posterior cam-post contact during squatting and stair climbing were observed in 0/17 knees and 0/0 knees, respectively. The Symptoms, Satisfaction, and Functional activities subscales of the KSS 2011 were significantly (P < 0.05) improved postoperatively compared to preoperatively (Symptoms, 10 to 21; Satisfaction, 15 to 26; Functional activities, 25 to 71).Conclusion: A gradual femoral radius component with an s-curve post-cam provided stable kinematics and favorable clinical results during squatting and stair climbing at 1 year after surgery.(c) 2021 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available