4.5 Article

Comparison between dry needling and focused ultrasound on the mechanical properties of the rat Achilles tendon: A pilot study

Journal

JOURNAL OF BIOMECHANICS
Volume 120, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.jbiomech.2021.110384

Keywords

Dry needling; Focused ultrasound; Tendon; Mechanical properties; Mechanical testing

Funding

  1. National Institutes of Health - National Institute of Biomedical Imaging and Bioengineering [R21EB027886]
  2. NSF Graduate Research Fellowship (Smallcomb) [DGE1255832]
  3. Penn State College of Engineering Multidisciplinary Seed Grant

Ask authors/readers for more resources

The study compared the effects of dry needling (DN) and focused ultrasound (fUS) on the mechanical properties and cell morphology of rat Achilles tendons. Results showed that fUS preserved the mechanical properties of tendons better than DN, with no significant cellular injury observed in the fUS group.
In the U.S., approximately 14 million tendon and ligament injuries are reported each year. Dry needling (DN) is a conservative treatment introduced to alleviate pain and restore function; however, it is invasive and has mixed success. Focused ultrasound (fUS) is a non-invasive technology that directs ultrasound energy into a well-defined focal volume. fUS induces thermal and/or mechanical bioeffects which can be controlled by the choice of ultrasound parameters. fUS could be an alternative to DN for treatment of tendon injuries, but the bioeffects must be established. Thus, the purpose of this pilot study was to compare the effect of DN and fUS on the mechanical properties and cell morphology of 30 ex vivo rat Achilles tendons. Tendons were randomly assigned to sham, DN, or fUS, with 10 tendons per group. Within each group, 5 tendons were evaluated mechanically, and 5 tendons were analyzed histologically. Elastic modulus in the DN (74.05 +/- 15.0 MPa) group was significantly lower than sham (149.84 +/- 59.1 MPa; p = 0.0094) and fUS (128.84 +/- 28.3 MPa; p = 0.0453) groups. Stiffness in DN (329.05 +/- 236.8 N/m m; p = 0.0034) and fUS (315.26 +/- 68.9 N/mm; p = 0.0027) groups were significantly lower than sham (786.10 +/- 238.7 N/mm) group. Histologically, localized necrosis was observed in 3 out of 5 tendons exposed to fUS, with surrounding tissue unharmed; no evidence of cellular injury was observed in DN or sham groups. These results suggest that fUS preserves the mechanical properties of tendon better than DN. Further studies are needed to evaluate fUS as an alternative, noninvasive treatment modality for tendon injuries. (c) 2021 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available