4.6 Article

Non-Invasive Estimation of Localized Dynamic Luminal Pressure Change by Ultrasound Elastography in Arteries With Normal and Abnormal Geometries

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 68, Issue 5, Pages 1627-1637

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2020.3028186

Keywords

Artery; elastography; luminal pressure; nonlinearity; shear modulus; strain; ultrasound

Funding

  1. National Natural Science Foundation of China (NSFC)/Research Grants Council (RGC) Joint Research Scheme [N_HKU713_15]

Ask authors/readers for more resources

The study established a mathematical model and conducted experiments to demonstrate the relationship among arterial wall deformation, stiffness, and luminal pressure, showing the effectiveness and accuracy of the proposed method for estimating dynamic luminal pressure changes.
Objective: Arterial wall deformation, stiffness, and luminal pressure are well-recognized predictors of cardiovascular diseases but intertwined. Establishing a relationship among these three predictors is therefore important for comprehensive assessment of the circulatory system, but very few studies focused on this. Methods: In this study, we first derived a mathematical description for localized luminal pressure change (Delta p) as a function of arterial wall strains (epsilon) and shear modulus (mu(T)) in the transverse plane; the arterial wall was modelled as a transversely isotropic and piecewise linearly-elastic material. Finite element simulations (FES) and in vitro fluid-driven inflation experiments were performed on arteries with both normal and abnormal geometries. epsilon and mu(T) in the experimental study were estimated by an ultrasound elastographic imaging framework (UEIF). Results: FES results showed good accuracy (percent errors <= 6.42%) of the proposed method for all simulated artery models. Experimental results showed good repeatability and reproducibility. Estimated (Delta p) over bar (pp) values (average peak-to-peak pressure change) compared with pressure meter measurements in two normal geometry phantoms and an excised aorta were 65.95 +/- 4.29 mmHg vs. 66.45 +/- 3.80 mmHg, 60.49 +/- 1.82 mmHg vs. 59.92 +/- 2.69, and 36.03 +/- 1.90 mmHg vs. 38.8 +/- 3.21 mmHg, respectively. For the artery with abnormal geometry mimicking a simple plaque shape, the feasibility of the proposed method for Delta p estimation was also validated. Conclusion: Results demonstrated that UEIF with the proposed mathematical model, which lumped wall deformation, stiffness and luminal pressure, could estimate the localized dynamic luminal pressure change noninvasively and accurately.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available