Keywords

Biochemical sensing; finite element method; multiparameter sensors; nanophotonics; surface plasmons

Ask authors/readers for more resources

The new quasi D-shaped plasmonic photonic crystal fiber microsensor with dual polarization enables simultaneous measurement of refractive index and temperature with high sensitivity and resolution. By incorporating special materials and design within the fiber structure, effective multiparameter sensing is achieved, with potential applications in various fields.
We present a new quasi D-shaped plasmonic photonic crystal fiber (PCF) microsensor with dual polarization for back-to-back measurement of refractive index (RI) and temperature. The PCF structure of the microsensor is form birefringent and supports two orthogonal polarizations for independent probing of both RI and temperature variations. Thin layers of tantalum pentoxide (Ta2O5) and gold (Au) are applied to the side-polished plane to form the RI sensing section. Furthermore, four micro air holes in the lower part of its outer cladding ring are gold-coated and selectively infiltrated with a temperature-sensitive liquid. A detailed investigation and numerical analyses of the coupling characteristics and sensing responses are presented using the finite element method (FEM) with a circular perfectly matched layer (PML). The RI metrics show a maximum wavelength sensitivity of 5000 nm/RIU and a maximum amplitude sensitivity of 266.54.RIU-1 from 1.35 to 1.46 RI range in the specified operating wavelength range of 1.25-1.65 mu m. The corresponding RI resolution is 2.0 x 10(-5) RIU. For the temperature sensing metrics, a maximum amplitude sensitivity of 4.8 x 10(-2) degrees C-1, a maximum wavelength sensitivity of 3.0 nm/degrees C, and a maximum resolution of 3.33 x 10(-2) degrees C from -50 degrees C to 50 degrees C is achieved. With appropriate instrumentation incorporating a polarization selector, the microsensor can double as a real-time simultaneous multiparameter sensor. Applications for the proposed microsensor can be found in molecular science, medical measurement and analysis, terrestrial environmental engineering and data assessment, aquatic ecosystem investigations, pharmaceutical and alimentary process control and validation, cryogenic studies, and several others.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available