4.7 Article

Can T2-weighted Dixon fat-only images replace T1-weighted images in degenerative disc disease with Modic changes on lumbar spine MRI?

Journal

EUROPEAN RADIOLOGY
Volume 31, Issue 12, Pages 9380-9389

Publisher

SPRINGER
DOI: 10.1007/s00330-021-07946-2

Keywords

Low back pain; Intervertebral disc degeneration; Magnetic resonance imaging

Ask authors/readers for more resources

The study demonstrated that an MRI protocol consisting of only sagittal T2-weighted Dixon fat and water images provided good diagnostic performance and interobserver agreement in lumbar degenerative disc disease with Modic changes, suggesting it could be a viable option for a shortened MRI protocol.
Objectives To evaluate the diagnostic performance and interobserver agreement of a magnetic resonance imaging (MRI) protocol that only includes sagittal T2-weighted Dixon fat and water images as an alternative to a standard protocol that includes both sagittal T1-weighted sequence and T2-weighted Dixon water images as reference standard in lumbar degenerative disc disease with Modic changes. Methods From February 2017 to March 2019, 114 patients who underwent lumbar spine MRI for low back pain were included in this retrospective study. All MRI showed Modic changes at least at one vertebral level. Two radiologists read the standard protocol and 1 month later the alternative protocol. All MRI were assessed for Modic changes (types, location, extension) as well as structural changes (endplate defects, facet arthropathy, spinal stenosis, foraminal stenosis, Schmorl nodes, spondylolisthesis, disc bulges, and degeneration). Interobserver agreement was assessed, as well as diagnostic performance using the standard protocol as reference standard. Results Interobserver agreement was moderate to excellent (kappa ranging from 0.51 to 0.92). Diagnostic performance of the alternative protocol was good for detection of any Modic change (sensitivity = 100.00% [95% CI, 99.03-100.00]; specificity = 98.89% [95% CI, 98.02-99.44]), as well as for detection of each Modic subtype and structural variables (sensitivity respectively 100% and ranging from 88.43 to 99.75% ; specificity ranging respectively from 97.62 to 100% and 99.58 to 99.91% ). Conclusions Combined with T2-weighted Dixon water images, T2-weighted Dixon fat images provide good diagnostic performance compared to T1-weighted images in lumbar degenerative disc disease with Modic changes, and could therefore allow for a shortened protocol.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available