4.4 Article

Redundancy in the International Anorectal Physiology Working Group Manometry Protocol: A Diagnostic Accuracy Study in Fecal Incontinence

Journal

DIGESTIVE DISEASES AND SCIENCES
Volume 67, Issue 3, Pages 964-970

Publisher

SPRINGER
DOI: 10.1007/s10620-021-06994-4

Keywords

Anorectal dysfunction; High-resolution anorectal manometry; Fecal incontinence; International Anorectal Physiology Working Group; The IAPWG protocol; The London classification

Ask authors/readers for more resources

The study showed that a 30-second resting anal pressure, analysis of 2 short squeezes with a 20-second between-maneuver recovery optimizes study duration without compromising diagnostic accuracy, indicating redundancy in the IAPWG protocol.
Background Anorectal manometry (ARM) is essential for identifying sphincteric dysfunction. The International Anorectal Physiology Working Group (IAPWG) protocol and London Classification provide a standardized format for performing and interpreting ARM. However, there is scant evidence to support timing and number of constituent maneuvers. Aims To assess the impact of protocol modification on diagnostic accuracy in patients with fecal incontinence. Methods Retrospective analysis of high-resolution ARM recordings from consecutive patients based on the current IAPWG protocol and modifications thereof: (1) baseline rest period (60 vs. 30 vs. 10 s); (2) number of abnormal short squeezes (SS) out of 3 (SS1/SS2/SS3) based on maximal incremental squeeze pressures over 5 s; (3) resting anal pressures (reflecting recovery) at 25-30 versus 15-20 s after SS1. Results One hundred patients (86 F, median age 55 [IQR: 39-65]; median St. Mark's incontinence score 14 [10-17]) were studied. 26% and 8% had anal hypotonia and hypertonia, respectively. Compared with 60-s resting pressure, measurements had perfect correlation (kappa = 1.0) over 30 s, and substantial correlation (kappa = 0.85) over 10 s. After SS1, SS2, and SS3, 43%, 49%, and 46% had anal hypocontractility, respectively. Correlation was substantial between SS1 and SS2 (kappa = 0.799) and almost perfect between SS2 and SS3 (kappa = 0.9). Compared to resting pressure of 5 s before SS1, pressure recordings at 25-30 and 15-20 s after SS1 were significantly correlated. Conclusions A 30-s resting anal pressure, analysis of 2 short-squeezes with a 20-s between-maneuver recovery optimizes study duration without compromising diagnostic accuracy. These findings indicate the IAPWG protocol has redundancy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available