Journal
BMC CANCER
Volume 21, Issue 1, Pages -Publisher
BMC
DOI: 10.1186/s12885-021-08216-6
Keywords
Prostatic neoplasms; Prostate-specific antigen; Image-guided biopsy
Categories
Funding
- Chungnam National University, Republic of Korea
Ask authors/readers for more resources
The study suggests that PSAD and ETzD may be more sensitive and accurate than traditional PSA for patients with gray zone PSA levels undergoing prostate biopsy. Increasing the cut-off values of PSAD and ETzD helps reduce unnecessary prostate biopsies.
Background Serum prostate-specific antigen (PSA) is widely used in screening tests for prostate cancer. As the low specificity of PSA results in unnecessary and invasive prostate biopsies, we evaluated the clinical significance of various PSAs and PSA density (PSAD) related to peripheral zones in patients with gray zone PSA level (4-10 ng/mL). Methods A total of 1300 patients underwent transrectal ultrasonography-guided prostate biopsy from 2014 to 2019. Among them, 545 patients in the gray zone were divided into the prostate cancer diagnosis group and the non-prostate cancer diagnosis group, and PSA, relative extra transitional zone PSA (RETzPSA), estimated post holmium laser enucleation of the prostate PSA (EPHPSA), PSAD, peripheral zone PSA density (PZPSAD) and extra-transitional zone density (ETzD) were compared and analyzed using receiver-operating characteristics (ROC) analysis after 1:1 matching using propensity score. Results Area under the ROC curve values of PSA, EPHPSA, RETzPSA, PSA density, ETzD, and PZPSAD were 0.553 (95% CI: 0.495-0.610), 0.611 (95% CI: 0.554-0.666), 0.673 (95% CI: 0.617-0.725), 0.745 (95% CI: 0.693-0.793), 0.731 (95% CI: 0.677-0.780) and 0.677 (95% CI: 0.611-0.719), respectively. PSAD had 67.11% sensitivity, 71.71% specificity, and 70.34% positive predictive rate at 0.18 ng/mL/cc. ETzD had 69.08% sensitivity, 64.47% specificity, and 66.04% positive predictive rate at 0.04 ng/mL/cc. When the cut-off value of PSAD was increased to 0.18 ng/mL/cc, the best results were obtained with an odds ratio of 5.171 (95% CI: 3.171-8.432), followed by ETzD with 4.054 (95% CI: 2.513-6.540). Conclusions These results suggested that volume-adjusted parameters (ETzD and PSAD) might be more sensitive and accurate than various PSA in gray zone patients who required prostate biopsy to reduce unnecessary biopsy.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available