4.6 Article

Design of an automatic hybrid system for removal of eye-blink artifacts from EEG recordings

Journal

BIOMEDICAL SIGNAL PROCESSING AND CONTROL
Volume 67, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.bspc.2021.102543

Keywords

Adaptive noise canceller; Electroencephalogram (EEG); Eye-blink artifact; Independent component analysis; Modified Z-score

Ask authors/readers for more resources

This paper introduces a hybrid system to automatically remove eye-blink artifacts from EEG by combining multiple methods. The proposed method showed better performance and does not require external electrodes for measuring eye-blink artifacts, ensuring comfortable measurements for patients.
Electroencephalography (EEG) signals are frequently used in several areas, such as diagnosis of diseases and BCI applications. It is important to remove noise sources for applications using EEG. This paper introduces a hybrid system to automatically remove eye-blink artifacts from the EEG by combining several methods, such as Independent Component Analysis (ICA), Kurtosis, K-means, Modified Z-Score (MZS) and Adaptive Noise Canceller (ANC). In the proposed method, all EEG recordings are first decomposed, and then the components related to the eye-blink artifacts are detected using Kurtosis and K-means. The MZS is used to detect regions of only eye-blink artifacts in the independent component. The classical Least Mean Squares (LMS) and Normalized LMS (NLMS) algorithms are used in the proposed ANC system. To comprehensively test the performance of the proposed method, simulated and real-world EEG datasets are used. The proposed system is compared with ANC systems having different reference inputs, Zeroing-ICA, and OD-ICA. In the simulated EEG dataset, the obtained overall RE, CC, SAR, SNR, Sensitivity, Specificity, and Area Under Curve (AUC) values are 0.1505, 0.9875, 1.3863, 2.7708, 100%, 93.8%, and 0.9380, respectively. In the real-world dataset, the obtained overall RE, CC, SAR, and SNR values are 0.0252, 0.9916, 2.8439, and 5.6944, respectively. The results suggest that the proposed method exhibits better performance concerning the given criteria. The proposed system does not require an external electrode for measuring eye-blink artifacts. This distinct advantage provided ensures a comfortable measurement for patients during long-term EEG recordings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available