4.8 Article

Toward Compact High-Performance Ion Mobility Spectrometers: Ion Gating in Ion Mobility Spectrometry

Journal

ANALYTICAL CHEMISTRY
Volume 93, Issue 15, Pages 6062-6070

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.0c04140

Keywords

-

Ask authors/readers for more resources

Printed circuit board (PCB) based drift tube ion mobility spectrometers offer the capability to manufacture compact devices with excellent performance at minimum cost. The study investigates the effects of different ion shutters and reaction region geometries on resolving power and detection limits, showing that the Bradbury-Nielsen shutter performs best in discriminating slow ion species and achieving low detection limits with a nickel-63 ionization source.
Printed circuit board (PCB) based drift tube ion mobility spectrometers enable the use of state-of-the-art production techniques to manufacture compact devices with excellent performance at minimum cost. The new PCB ion mobility spectrometer (PCB-IMS) presented here is equipped with either a 140 MBq tritium or a 95 MBq nickel-63 ionization source and consists of a combination of horizontally arranged 6-layer PCBs for the drift and reaction regions and vertically arranged PCBs for interfacing the ionization source, ion shutter, and detector. The design allows the reproducible manufacturing and thus comparison of different IMS topologies. Here, we investigate different ion shutters, field-switching, Bradbury-Nielsen, and tristate and their effects on resolving power and limits of detection considering two different ionization region geometries and ionization sources, tritium and nickel-63. It is shown that the high resolving power of R-P > 80 at low drift voltage of 3 kV and short drift length of 50 mm can be achieved independent of the used ion shutter mechanism and reaction region geometry. While the resolving power of all ion shutters is excellent, the Bradbury-Nielsen shutter shows a pronounced discrimination of slow ion species when using short shutter opening times for small initial ion cloud widths, as required for high resolving power. Thus, the intensity of the proton-bound dimer of 2-pentanone is reduced by 30% compared to the signal intensity obtained with both the field-switching and tristate shutter. The detection limits employing the Bradbury-Nielsen shutter and a 50 mm reaction region as required for nickel-63 are 58 ppt(v) for the protonated monomer and 3.4 ppb(v) for the proton-bound dimer of 2-pentanone. The detection limits achieved with the tristate shutter utilizing the same reaction region are slightly higher for the protonated monomer at 68 pptv, but lower for the proton-bound dimer at 2 ppbv due to the advanced ion shutter principle not discriminating slow ions. However, the lowest detection limits of 13 pptv and 301 pptv can be achieved with the field-switching shutter and a 2 mm reaction region, sufficient for a tritium ionization source.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available