4.8 Article

Sensitive Dual-Mode Biosensors for CYFRA21-1 Assay Based on the Dual-Signaling Electrochemical Ratiometric Strategy and On-Off-On PEC Method

Journal

ANALYTICAL CHEMISTRY
Volume 93, Issue 17, Pages 6801-6807

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c00746

Keywords

-

Funding

  1. NSFC [22074033, 21727810]

Ask authors/readers for more resources

In this study, a dual-mode biosensor was developed for sensitive detection of CYFRA21-1, demonstrating great potential for applications in biological analysis and early disease diagnosis.
Herein, an electrochemical (EC)-photoelectrochemical (PEC) dual-mode biosensor was constructed for cytokeratin 19 fragment 21-1 (CYFRA21-1) assay based on the dual-signaling electrochemical ratiometric strategy and on-off-on PEC method. The indium tin oxide (ITO) electrode was modified by 3,4,9,10-perylenetetracarboxylic dianhydride (PTCDA)@C-60 and gold nanoparticles (Au NPs), and the double-stranded DNA composed of thiol/methylene blue (MB)-labeled single-stranded DNA (ssDNA) (S0-MB) and antibody/ferrocene (Fc)-labeled ssDNA (Ab1-S1-Fc) was immobilized on the Au NPs/PTCDA@C-60/ITO electrode via the Au-S bond between Au NPs and thiol of S0-MB. With the help of another antibody-labeled ssDNA (Ab2-S2), the presence of CYFRA21-1 triggered a typical antigen-antibody sandwich immune reaction (Ab1, CYFRA21-1, and Ab2) and proximity hybridization between Ab1-S1-Fc and Ab2-S2. This caused the release of Ab1-S1-Fc from the modified electrode and the change of S0-MB to a hairpin structure, resulting in a decrease (an increase) of the oxidation peak current of Fc (MB) and an increase of the photocurrent due to the enhancing (inhibiting) effect of MB (Fc) on the photoelectric performance of the Au NPs/PTCDA@C-60/ITO electrode. Thus, CYFRA21-1 was detected by the developed EC-PEC dual-mode sensing platform sensitively, and the linear response ranges of 0.001-40 ng/mL with a detection limit of 0.3 pg/mL for the EC technique and 0.0001-4 ng/mL with a detection limit of 0.03 pg/mL for the PEC method were obtained. Furthermore, by changing the specific antibodies of disease-related biomarkers, the developed dual-mode biosensing platform could be readily extended to detect other antigens, implying its great potential applications in biological analysis and early disease diagnosis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available