4.3 Article

Clinical and radiological outcomes of acetabular revision surgery with trabecular titanium cups in Paprosky type II and III bone defects

Journal

JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY
Volume 22, Issue 1, Pages -

Publisher

SPRINGER
DOI: 10.1186/s10195-021-00571-1

Keywords

Revision total hip arthroplasty; Acetabular bone loss; Acetabular reconstruction; Trabecular titanium cup

Categories

Ask authors/readers for more resources

The study evaluated the mid-term clinical outcomes and radiographic stability of two different types of cementless trabecular titanium acetabular components in total hip revision surgery, showing good clinical and radiographic results at mid-term follow-up for patients with Paprosky type II and III bone defects.
Background This prospective study aims to evaluate the mid-term clinical outcomes and radiographic stability of two different types of cementless trabecular titanium acetabular components in total hip revision surgery. Methods Between December 2008 and February 2017, 104 cup revisions were performed using trabecular titanium revision cups. Mean age of patients was 70 (range 29-90; SD 11) years. The majority of revisions were performed for aseptic loosening (86 cases, 82.69%), but in all the other diagnoses (18 cases), a significant bone loss (Paprosky type II or III) was registered preoperatively. Bone defects were classified according to Paprosky acetabular classification. We observed 53 type II defects and 42 type III defects. Cups were chosen according to the type of defect. Results Average follow-up was 91 (range 24-146) months. Mean Harris Hip Score (HHS) improved from 43.7 (range 25-70; SD 9) preoperatively to 84.4 (range 46-99; SD 7.56) at last follow-up. One (1.05%) cup showed radiographic radiolucent lines inferior to 2 mm and was clinically asymptomatic. One (1.05%) cup was loose and showed periacetabular allograft reabsorption. Kaplan-Meier survivorship was assessed to be 88.54% (95% CI 80.18-93.52%) at 71 months, with failure of the cup for any reason as the endpoint. Conclusion Trabecular titanium revision cups showed good clinical and radiographic results at mid-term follow-up in Paprosky type II and III bone defects.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available