4.5 Article

Eligibility for subcutaneous implantable cardioverter-defibrillator in adults with congenital heart disease

Journal

ESC HEART FAILURE
Volume 8, Issue 2, Pages 1502-1508

Publisher

WILEY PERIODICALS, INC
DOI: 10.1002/ehf2.13243

Keywords

Subcutaneous implantable cardioverter-defibrillator; Adult congenital heart disease; S-ICD screening test; Tetralogy of Fallot

Funding

  1. Project DEAL

Ask authors/readers for more resources

This study screened 100 ACHD patients for S-ICD eligibility and found an eligibility rate of 83%, with automated screening test being an effective tool. A QRS duration >= 148 ms was identified as the only independent predictor for S-ICD screening failure.
Aims Patients with adult congenital heart disease (ACHD) carry an increased risk for sudden cardiac death. Implantable cardioverter-defibrillator (ICD) therapy may be challenging in these patients due to anatomical barriers, repeated cardiac surgery, or complicated transvenous access. Thus, the subcutaneous ICD (S-ICD) can be a promising alternative in this patient population. Patients with ACHD show significant electrocardiogram (ECG) abnormalities, which could affect S-ICD sensing because it depends on surface ECG. Methods and results One hundred patients with ACHD were screened for S-ICD eligibility. Standard ECG-based screening test and automated S-ICD screening test were performed in all patients. Sixty-six patients (66%) were male. Underlying congenital heart disease (CHD) was mainly CHD of great complexity (71%) and moderate complexity (29%), including repaired tetralogy of Fallot (20%), which was the most common entity. Thirty-seven patients (37%) already had a pacemaker (23%) or ICD (14%) implanted. Automated screening test identified 83 patients (83%) eligible for S-ICD implantation in either left parasternal position (78%) or right parasternal position (75%). Absence of sinus rhythm, QRS duration, and a paced QRS complex were associated with S-ICD screening failure in univariate analysis. Receiver operating characteristic curve and multivariate analysis revealed a QRS duration >= 148 ms as the only independent predictor for S-ICD screening failure. Conclusions Patients with ACHD show satisfactory eligibility rates (83%) for S-ICD implantation utilizing the automated screening test, including patients with CHD of high complexity. S-ICD therapy should be considered with caution in ACHD patients with a QRS duration >= 148 ms and/or need for ventricular pacing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available