A Novel Helical Superconducting Fault Current Limiter for Electric Propulsion Aircraft

Journal

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TTE.2020.2998417

Keywords

Windings; Loss measurement; Aircraft propulsion; Current measurement; High-temperature superconductors; Fault currents; Voltage measurement; AC loss; electric propulsion aircraft system (EPAS); helical bifilar coil; quench performance; superconducting fault current limiter (SFCL)

Funding

  1. U.K. Engineering and Physical Sciences Research Council (EPSRC) [EP/S000720/1]
  2. U.K. Royal Society International Exchanges 2018 Cost Share (China), Advanced DC Fault Protection by Integration of Superconducting Fault Current Limiter (SFCL) With DC Circuit Breaker [IEC\NSFC\181111]
  3. EPSRC [EP/S000720/1] Funding Source: UKRI

Ask authors/readers for more resources

It is crucial to achieve a high safety and reliability standard in future electric propulsion aircraft (EPA). The superconducting fault current limiter (SFCL) showed promising results in experiments with the proposed helical bifilar coil connected in series (BCS).
It is crucial to achieve a high safety and reliability standard in future electric propulsion aircraft (EPA). Due to low short-circuit impedance and high rate of fault current rise in EPA systems, the superconducting fault current limiter (SFCL) plays a promising role, with advantages of lightweight, high efficiency, and compact size compared with conventional FCL. A novel helical bifilar coil is proposed, which is composed of two windings wound in opposite directions on the same bobbin; these are connected in series to achieve equal current sharing and a noninductive circuit. The 12-mm-wide stainless steel-reinforced superconducting tape from AMSC was used for the windings. To characterize the proposed helical bifilar coil connected in series (BCS), AC loss tests under three frequencies and quench tests under prospective fault current up to 2223 A were carried out. They were compared with the results measured from a conventional helical bifilar coil connected in parallel (BCP) that had an identical specification to the BCS. It was concluded that the AC losses measured in the BCP are dependent on the current and frequency. The fault current was suppressed effectively by the BCS at the first half peak from 2223 to 495 A, corresponding to 22.3% of the prospective fault current. The quench performance of BCP was also tested and discussed.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available