4.6 Article

Development of Rapid and High-Precision Colorimetric Device for Organophosphorus Pesticide Detection Based on Microfluidic Mixer Chip

Journal

MICROMACHINES
Volume 12, Issue 3, Pages -

Publisher

MDPI
DOI: 10.3390/mi12030290

Keywords

colorimetric device; organophosphorus pesticide residues; microfluidics; LCD mask photo-curing

Funding

  1. China Postdoctoral Science Foundation [2019M653761]
  2. Provincial Innovation and Entrepreneurship Training Program of Northwest AF University [S201910712099]

Ask authors/readers for more resources

This study proposed a colorimetric device based on a microfluidic mixer chip for rapid and high-precision detection of organophosphorus pesticide residues, with a minimum detection concentration of 0.045 mg/L and an average detection time of 60 seconds. The results provide a theoretical and experimental basis for portable and high-precision detection of pesticide residues.
The excessive pesticide residues in cereals, fruit and vegetables is a big threat to human health, and it is necessary to develop a portable, low-cost and high-precision pesticide residue detection scheme to replace the large-scale laboratory testing equipment for rapid detection of pesticide residues. In this study, a colorimetric device for rapid detection of organophosphorus pesticide residues with high precision based on a microfluidic mixer chip was proposed. The microchannel structure with high mixing efficiency was determined by fluid dynamics simulation, while the corresponding microfluidic mixer chip was designed. The microfluidic mixer chip was prepared by a self-developed liquid crystal display (LCD) mask photo-curing machine. The influence of printing parameters on the accuracy of the prepared chip was investigated. The light source with the optimal wavelength of the device was determined by absorption spectrum measurement, and the relationship between the liquid reservoir depth and detection limit was studied by experiments. The correspondence between pesticide concentration and induced voltage was derived. The minimum detection concentration of the device could reach 0.045 mg center dot L-1 and the average detection time was reduced to 60 s. The results provide a theoretical and experimental basis for portable and high-precision detection of pesticide residues.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available