4.5 Article

Standardization of three-dimensional pose of cylindrical implants from intraoral radiographs: a preliminary study

Journal

BMC ORAL HEALTH
Volume 21, Issue 1, Pages -

Publisher

BMC
DOI: 10.1186/s12903-021-01448-9

Keywords

Dental informatics; bioinformatic; Computer simulation; Dental implant(s); Digital imaging; radiology; Mathematical modeling

Ask authors/readers for more resources

This study introduced a theoretical solution to describe the pose of a cylindrical dental fixture on radiographs and experimentally validated the method. The results showed that the method effectively calculated the angles and lengths of dental implants and allowed for post-standardization of two-dimensional radiographs.
Background To introduce a theoretical solution to a posteriori describe the pose of a cylindrical dental fixture as appearing on radiographs; to experimentally validate the method described. Methods The pose of a conventional dental implant was described by a triplet of angles (phi-pitch, theta-roll, and psi-yaw) which was calculated throughout vector analysis. Radiographic- and simulated-image obtained with an algorithm were compared to test effectiveness, reproducibility, and accuracy of the method. The length of the dental implant as appearing on the simulated image was calculated by the trigonometric function and then compared with real length as it appeared on a two-dimensional radiograph. Results Twenty radiographs were analyzed for the present in silico and retrospective study. Among 40 fittings, 37 resulted as resolved with residuals <= 1 mm. Similar results were obtained for radiographic and simulated implants with absolute errors of - 1.1 degrees +/- 3.9 degrees for phi; - 0.9 degrees +/- 4.1 degrees for theta; 0 degrees +/- 1.1 degrees for psi. The real and simulated length of the implants appeared to be heavily correlated. Linear dependence was verified by the results of the robust linear regression: 0.9757 (slope), + 0.1344 mm (intercept), and an adjusted coefficient of determination of 0.9054. Conclusions The method allowed clinicians to calculate, a posteriori, a single real triplet of angles (phi, theta, psi) by analyzing a two-dimensional radiograph and to identify cases where standardization of repeated intraoral radiographies was not achieved. The a posteriori standardization of two-dimensional radiographs could allowed the clinicians to minimize the patient's exposure to ionizing radiations for the measurement of marginal bone levels around dental implants.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available