4.6 Article

Simultaneous Measurement of Temperature and Refractive Index Using High Temperature Resistant Pure Quartz Grating Based on Femtosecond Laser and HF Etching

Journal

MATERIALS
Volume 14, Issue 4, Pages -

Publisher

MDPI
DOI: 10.3390/ma14041028

Keywords

hollow needle; temperature sensing; refractive index sensing; optical fiber sensor; fiber Bragg grating (FBG); femtosecond laser; hydrofluoric acid

Funding

  1. Postdoctoral Innovative Talent Support Program [BX20200274]
  2. National Natural Science Foundation of China [51805421, 51720105016, 91748207]

Ask authors/readers for more resources

The study developed a dual-parameter sensor based on FBG, which can simultaneously measure temperature and refractive index, achieving precise measurements of high temperature and refractive index, showing great potential in acupuncture treatment.
The optical fiber temperature and refractive index sensor combined with the hollow needle structure for medical treatment can promote the standardization of traditional acupuncture techniques and improve the accuracy of body fluid analysis. A double-parameter sensor based on fiber Bragg grating (FBG) is developed in this paper. The sensor materials are selected through X-ray diffraction (XRD) analysis, and the sensor sensing principle is theoretically analyzed and simulated. Through femtosecond laser writing pure silica fiber, a high temperature resistant wavelength type FBG temperature sensor is obtained, and the FBG is corroded by hydrofluoric acid (HF) to realize a high-sensitivity intensity-type refractive index sensor. Because the light has dual characteristics of energy and wavelength, the sensor can realize simultaneous dual-parameter sensing. The light from the lead-in optical fiber is transmitted to the sensor and affected by temperature and refractive-index; then, the reflection peak is reflected back to the lead-out fiber by the FBG. The high temperature response and the refractive index response of the sensor were measured in the laboratory, and the high temperature characteristics of the sensor were verified in the accredited institute. It is demonstrated that the proposed sensor can achieve temperature sensing up to 1150 degrees C with the sensitivity of 0.0134 nm/degrees C, and refractive sensing over a refractive range of 1.333 to 1.4027 with the sensitivity of -49.044 dBm/RIU. The sensor features the advantages of two-parameter measurement, compact structure, and wide temperature range, and it exhibits great potential in acupuncture treatment.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available