4.6 Article

Idealized 3D Auxetic Mechanical Metamaterial: An Analytical, Numerical, and Experimental Study

Journal

MATERIALS
Volume 14, Issue 4, Pages -

Publisher

MDPI
DOI: 10.3390/ma14040993

Keywords

3D printing; mechanical metamaterial; auxetics; negative Poisson's ratio; 3D re-entrant

Ask authors/readers for more resources

In this study, an auxetic metamaterial structure known as idealized 3D re-entrant structure was analyzed, numerically calculated, and experimentally tested for its mechanical properties and Poisson's ratio using different methods. The results showed that the structure's Poisson's ratio is most influenced by the angle theta related to tension-dominated struts, while angle phi related to compression-dominated struts had the least influence, with compression-dominated struts providing strength and stiffness to the structure. Additionally, it was demonstrated that the structure could potentially have a zero Poisson's ratio within a specific range of theta and phi angles.
Mechanical metamaterials are man-made rationally-designed structures that present unprecedented mechanical properties not found in nature. One of the most well-known mechanical metamaterials is auxetics, which demonstrates negative Poisson's ratio (NPR) behavior that is very beneficial in several industrial applications. In this study, a specific type of auxetic metamaterial structure namely idealized 3D re-entrant structure is studied analytically, numerically, and experimentally. The noted structure is constructed of three types of struts-one loaded purely axially and two loaded simultaneously flexurally and axially, which are inclined and are spatially defined by angles theta and phi. Analytical relationships for elastic modulus, yield stress, and Poisson's ratio of the 3D re-entrant unit cell are derived based on two well-known beam theories namely Euler-Bernoulli and Timoshenko. Moreover, two finite element approaches one based on beam elements and one based on volumetric elements are implemented. Furthermore, several specimens are additively manufactured (3D printed) and tested under compression. The analytical results had good agreement with the experimental results on the one hand and the volumetric finite element model results on the other hand. Moreover, the effect of various geometrical parameters on the mechanical properties of the structure was studied, and the results demonstrated that angle theta (related to tension-dominated struts) has the highest influence on the sign of Poisson's ratio and its extent, while angle phi (related to compression-dominated struts) has the lowest influence on the Poisson's ratio. Nevertheless, the compression-dominated struts (defined by angle phi) provide strength and stiffness for the structure. The results also demonstrated that the structure could have zero Poisson's ratio for a specific range of theta and phi angles. Finally, a lightened 3D re-entrant structure is introduced, and its results are compared to those of the idealized 3D re-entrant structure.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available