4.6 Article

An 18-Month Analysis of Bond Strength of Hot-Dip Galvanized Reinforcing Steel B500SP and S235JR+AR to Chloride Contaminated Concrete

Journal

MATERIALS
Volume 14, Issue 4, Pages -

Publisher

MDPI
DOI: 10.3390/ma14040747

Keywords

concrete; reinforcing steel; bond strength; zinc coating; HDG; corrosion; chlorides; pullout; EIS; LPR; optical measurements; 3D scanning

Funding

  1. Silesian University of Technology (Poland) [03/020/RGP_19/0072]
  2. [BK-281/RB-2/2021 (03/020/BK_21/0103)]

Ask authors/readers for more resources

This article presents a comparative analysis of bond strength tests between hot-dip galvanized and black steel rebars to concrete with and without chlorides. The presence of zinc coating on rebars was found to impact anchorage parameters, and the stiffness of rebar anchorage was significantly higher in chloride contaminated concrete compared to concrete without chlorides.
This article describes the comparative analysis of tests on bond strength of hot-dip galvanized and black steel to concrete with and without chlorides. The bond effect was evaluated with six research methods: strength, electrochemical (measurements of potential, EIS and LPR), optical, and 3D scanning. The tests were conducted within a long period of 18 months on 48 test elements reinforced with smooth rebars phi 8 mm from steel grade S235JR+AR and ribbed rebars phi 8 mm and phi 16 mm from steel grade B500SP. The main strength tests on the reinforcement bond to concrete were used to compare forces pulling out galvanized and black steel rebars from concrete. This comparative analysis was performed after 28, 180, and 540 days from the preparation of the elements. The electrochemical tests were performed to evaluate corrosion of steel rebars in concrete, particularly in chloride contaminated concrete. The behaviour of concrete elements while pulling out the rebar was observed using the system of digital cameras during the optical tests. As regards 3D scanning of ribbed rebars phi 8 mm and phi 16 mm, this method allowed the detailed identification of their complex geometry in terms of determining the polarization area to evaluate the corrosion rate of reinforcement in concrete. The test results indicated that the presence of zinc coating on rebars had an impact on the parameters of anchorage. In the case of ribbed rebars of 16 mm in diameter, the maximum values of adhesive stress and bond stiffness were reduced over time when compared to black steel rebars. Moreover, it was noticed that the stiffness of rebar anchorage in chloride contaminated concrete was considerably higher than in concrete without chlorides.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper