4.5 Article

A multiplex real-time PCR quantitation of human herpesvirus-6, 7, 8 viruses: application in blood transfusions

Journal

VIROLOGY JOURNAL
Volume 18, Issue 1, Pages -

Publisher

BMC
DOI: 10.1186/s12985-021-01510-6

Keywords

Human herpesvirus; Pityriasis rosea; Blood transfusion; Multiplex real-time PCR

Categories

Ask authors/readers for more resources

Fluorescent quantitative PCR assay is widely used for detecting viral DNA, but a new method has been developed to simultaneously detect HHV-6, 7, and 8. Through blood sample collection and PCR optimization, a triple fluorescent quantitative PCR detection system was constructed for the simultaneous detection of HHV-6, 7, and 8. The method showed good specificity and sensitivity in blood transfusion screening.
BackgroundIn recent years, fluorescent quantitative polymerase chain reaction assays for detecting viral DNA are in widespread use throughout the world. However, considering the wide distribution of new herpesvirus among the population, we constructed a method to detect HHV-6, 7, and 8 simultaneously.MethodsThe blood samples of 74 blood donors and 45 pityriasis rosea patients were collected. The recombinant plasmids containing U67, U36, and orf65 were constructed to optimize the PCR reaction system. The forward and reverse primers and probe sequences of HHV-6 were as follows: TAAATATCGATGCCGCTCTG, ACGTTCTAGCCATCTTCTTTG, CGCAAACGACAAAGCCA. The forward and reverse primers and probe sequences of HHV-7 were as follows: TTAGACATCTTACACGACAGC, CAGCTTTTCGAACTTGTCAC, TTCATCGGGTACGTCCA. The forward and reverse primers and probe sequences of HHV-8 were as follows: GCGACATATTTCCCTGATCC, CCAACTTTAAGGTGAGAGACC, CATGCGAGCCACCAG. Through the detection of housekeeping genes, DNA sequencing, and optimization of the PCR reaction system, the triple fluorescent quantitative PCR detection system was constructed. Blood samples of blood transfusion staff and pityriasis rosea patients were detected.ResultsThe correlations of HHV-6, 7, and 8 between single and multiplex PCR are 0.980, 0.987, 0.965, respectively. In 74 blood donor samples, 16.2% of HHV-6 and 55% of HHV-7 were positive (viral load>3 log10 copies/ml) according to multiplex real-time PCR. In 45 patients suspected of pityriasis rosea (PR) infection, 40% HHV-6, 73.3% positive cases are found.ConclusionWith the safety of blood transfusion being a major concern of the public, this method will show good specificity and sensitivity in blood transfusion screening.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available