4.6 Article

Simultaneous determination of platinum group elements and rhenium mass fractions in road dust samples using isotope dilution inductively coupled plasma-tandem mass spectrometry after cation exchange separation

Journal

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.sab.2020.106052

Keywords

-

Categories

Funding

  1. Science & Engineering Research Board (SERB) [EMR/2015/000439]
  2. Indian Institute of Technology Kanpur

Ask authors/readers for more resources

This study proposes a method for measuring PGE and Re mass fractions in road dust and rock samples with complex matrices, utilizing matrix removal, high pressure-high temperature digestion, isotope dilution calibration, cation exchange resin separation, and ICP-MS/MS measurements. Validation results show that the method provides accurate measurements with intermediate precision for PGE and Re mass fractions in environmental samples with complex matrices.
Measurement of Platinum Group Element (PGE: Ru, Rh, Pd, Os, Ir, and Pt) and Rhenium (Re) in environmental samples is a difficult task due to their ultra-trace level concentrations, and these metals suffer from severe isobaric and polyatomic interference. These kinds of issues have been solved for environmental samples having simple matrices such as tunnel dust and moss. However, a scope of improvement still exists in challenging sample matrices such as road dust, soil, and rocks. In this study, a method that enables measurement of PGE and Re mass fractions in road dust and rock samples is proposed. The method involves matrix removal using a cation-exchange column followed by measurement using inductively coupled plasma tandem mass spectrometry (ICP-MS/MS, also known as ICP-QQQ-MS) with 10% NH3 in He as reactive gas in Collision/Reaction Cell. This study emphasizes that the usage of a simple cation-exchange column is an important step over the framework developed by Suoranta et al., 2012, which was developed to measure PGE and Re fractions in environmental samples having a simpler matrix such as moss samples. The method combines high pressure (130 bars) and high temperature (220 degrees C) digestion procedure in combination with isotope dilution (ID) as a calibration strategy, PGE and Re separation using cation exchange resin, and their measurements using ICP-MS/MS. The method was validated with road dust (BCR-723) and ultramafic komatiite (OKUM) having a complex matrix. The measured PGE and Re mass fractions of the two-measured reference material show excellent agreement with their certified values and have intermediate precisions ranging from 0.4-7.7% RSD. We conclude that the combination of single-stage cation-exchange chromatography with ID-ICP-MS/MS measurements enables measurement results with uncertainties fit for purpose for PGE and Re mass fractions in environmental samples with a complex matrix.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available