4.6 Article

Consistency of Suspended Particulate Matter Concentration in Turbid Water Retrieved from Sentinel-2 MSI and Landsat-8 OLI Sensors

Journal

SENSORS
Volume 21, Issue 5, Pages -

Publisher

MDPI
DOI: 10.3390/s21051662

Keywords

MSI sensor; OLI sensor; remote sensing; suspended particulate matter; turbid water; consistency

Funding

  1. Natural Science Research Project of Anhui Universities [KJ2019A0045]
  2. Anhui Natural Science Foundation [1608085QD82]
  3. National Natural Science Foundation of China [41401022]

Ask authors/readers for more resources

The study found that the consistency of SPM concentration values retrieved from different satellite images using the same model or form of models is significantly better than using optimal models with different forms.
Research on the consistency of suspended particulate matter (SPM) concentration retrieved from multisource satellite sensors can serve as long-time monitoring of water quality. To explore the influence of the atmospheric correction (AC) algorithm and the retrieval model on the consistency of the SPM concentration values, Landsat 8 Operational Land Imager (OLI) and Sentinel 2 MultiSpectral Imager (MSI) images acquired on the same day are used to compare the remote sensing reflectance (Rrs) SPM retrieval values in two high-turbidity lakes. An SPM retrieval model for Shengjin Lake is established based on field measurements and applied to OLI and MSI images: two SPM concentration products are highly consistent (R-2 = 0.93, Root Mean Squared Error (RMSE) = 20.67 mg/L, Mean Absolute Percentage Error (MAPE) = 6.59%), and the desired results are also obtained in Chaohu Lake. Among the four AC algorithms (Management Unit of the North Seas Mathematical Models (MUMM), Atmospheric Correction for OLI'lite'(ACOLITE), Second Simulation of Satellite Signal in the Solar Spectrum (6S), Landsat 8 Surface Reflectance Code & Sen2cor (LaSRC & Sen2cor)), the two Rrs products, as well as the final SPM concentration products retrieved from OLI and MSI images, have the best consistency when using the MUMM algorithm in SeaWIFS Data Analyst System (SeaDAS) software. The consistency of SPM concentration values retrieved from OLI and MSI images using the same model or same form of models is significantly better than that retrieved by applying the optimal models with different forms.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available