4.6 Article

Triazine-based covalent porous organic polymer for the online in-tube solid-phase microextraction of polycyclic aromatic hydrocarbons prior to high-performance liquid chromatography-diode array detection

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1641, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.chroma.2021.462004

Keywords

Covalent organic porous polymer; Solid-phase microextraction; High-performance liquid chromatography; Polycyclic aromatic hydrocarbons; Online analysis

Funding

  1. National Natural Science Foundation of China (NSFC) [21777054]
  2. Shandong Provincial Natural Science Foundation of China [ZR2019MB058]

Ask authors/readers for more resources

A triazine-based covalent organic porous polymer (COP) with a rough surface and suitable extraction site was synthesized and employed in in-tube solid-phase microextraction combined with high-performance liquid chromatography-diode array detector for efficient extraction and sensitive detection of PAHs.
A triazine-based covalent organic porous polymer (COP) was synthesized from the monomers 1,3,5-triphenylbenzene and tricyanogen chloride via the Friedel-Crafts reaction and characterized in detail using Brunauer-Emmett-Teller analysis, X-ray photoelectron spectroscopy, elemental analysis, and scanning electron microscopy, which confirmed that the COP had a rough surface and suitable extraction site. It was then employed in in-tube solid-phase microextraction combined with a high-performance liquid chromatography-diode array detector. The COP adsorbent was evaluated with different types of analyte, including estrogens, polycyclic aromatic hydrocarbons (PAHs), and plasticizers. The COP produced its best performance with PAHs. In order to obtain the highest extraction efficiency for PAHs, the main influential factors were optimized. Furthermore, a sensitive analytical method was established with the limits of detection of 0.004-0.010 mu g L-1, high enrichment factor of 1110-2763, and wide linear ranges (0.013-20.0 mu g L-1, 0.016-20.0 mu g L-1 and 0.033-20.0 mu g L-1). The relative standard deviation in intra-day and interday tests was also controlled to be within 0.3-3.1%. The proposed method was employed in the online detection of trace PAHs in real water samples, with satisfactory results obtained. (C) 2021 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available