4.6 Article

Pseudotumors in Small-Head Metal-on-Metal Total Hip Arthroplasties at a Minimum Follow-Up of 20 Years

Journal

JOURNAL OF ARTHROPLASTY
Volume 36, Issue 8, Pages 2871-2877

Publisher

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2021.03.022

Keywords

metal-on-metal THA; long-term results; serum metal levels; pseudotumor; MRI correlation

Categories

Ask authors/readers for more resources

This study compared metal ion levels, pseudotumors, clinical, and radiological results in small-head MOM hips over a follow-up period of more than 20 years. The study found good long-term clinical and functional outcomes in patients, with no significant increase in serum metal levels in patients with pseudotumors.
Background: Metal-on-metal (MOM) surfaces in total hip arthroplasty (THA) have been used widely. Serum cobalt and chromium levels have been the standard investigation for follow-up examinations, but magnetic resonance imaging (MRI) with metal artifact reducing sequences has shown good results in detecting pseudotumors. The aim of this study is to survey a significant correlation among MRI findings, serum metal levels, and clinical scores in patients with small-head MOM implants and if serum cobalt and chromium levels are sufficient in detecting patients with pseudotumors in the long-term follow-up. Methods: At a minimum follow-up of 20 years, 26 patients (29 THAs) of the original 98 patients (105 THAs) included in this study between November 1992 and May 1994 were available for follow-up examination. Clinical scores, serum metal ion levels, and MRIs were obtained. Results: We found mean serum cobalt levels of 1.87 mu g/L (+/- 3.44) and chromium levels of 2.23 mu g/L (+/- 2.96) and very good clinical and functional results (mean Harris Hip Score 88.6) in the long-term follow-up. Pseudotumors were detected in MRIs of 21 hips. There were no significant differences between patients with or without pseudotumors regarding serum metal levels and the correlation for clinical outcome scores, demographic data, and cup inclination. The cumulative rate of survival was still at 91.4% at 22.8 years. Conclusion: This study presents the first published data on small-head MOM hips, comparing metal ion levels, pseudotumors, clinical, and radiological results in a follow-up period of more than 20 years and reveals that serum metal levels are not significantly higher in patients with pseudotumors. (C) 2021 The Authors. Published by Elsevier Inc.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available