4.4 Article

Sensitive Electrochemical Immunosensor for Detection of Mycotoxins Aflatoxin B1 Using Disposable screen-Printed Carbon Electrode

Journal

Publisher

ESG
DOI: 10.20964/2021.03.44

Keywords

Immunosensor; Aflatoxin B1; Cycle voltammetry; Differential pulse voltammetry; Linear range; Limit of detection

Funding

  1. TaiZhou 311 Project

Ask authors/readers for more resources

This study presented the preparation of a sensitive electrochemical immunosensor to detect Aflatoxin B1 (AFB1) and demonstrated its reliability and accuracy in determining AFB1 in real maize samples. The immunosensor exhibited stable and sensitive electrochemical responses, with comparable or better performance compared to other reported AFB1 immunosensors in the literature. The results also showed that the immunosensor had acceptable recovery and relative standard deviation values, confirming its practical utility in real sample analysis.
This study presented the preparation of sensitive electrochemical immunosensor to detect mycotoxins aflatoxin B1 (AFB1) by immobilization of monoclonal antibodies of AFB1 on disposable screen-printed carbon electrode (SPCE) surface (anti-AFB1/SPCE). The morphological and structural properties of prepared SPCE were studied by XRD and FESEM analysis which showed the carbon structure of SPCE covered the electrode surface with rough and porous morphology. Differential pulse voltammetry (DPV) and Cycle voltammetry (CV) techniques were applied to record the electrochemical responses of anti-AFB1/SPCE and SPCE. CV studies showed the electrochemical responses of anti-AFB1/SPCE were more stable and sensitive toward SPCE in [Fe(CN)6](3-/4-) as redox probe solution due to the synergistic effect between porous morphology of SPCE and immobilization of anti-AFB1 and its the great electrochemical reaction capability and fast rates of electron transfer on anti-AFB1/SPCE surface. DPV measurements showed the linear range and limit of detection of AFB1 on anti-AFB1/SPCE were obtained 10 to 120 ng.ml(-1) and 0.007 ng.ml(-1), respectively which illustrating the comparable or better electrochemical performance of anti-AFB1/SPCE for determination of AFB1 in comparison with other reported AFB1 immunosensors in literatures. Studying the capability of anti-AFB1/SPCE in a prepared real sample of maize showed the obtained AFB1 concentration in pure real solution was 9.73 ng ml(-1) that was consistent with the results obtained by high performance liquid chromatography method. Furthermore, results demonstrated the obtained recovery and relative standard deviation values were acceptable and the prepared immunosensor was reliable to determine AFB1 in real samples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available