4.7 Article

Thermal performance of an absorption-refrigeration system with [emim]Cu2Cl5/NH3 as working fluid

Journal

ENERGY
Volume 112, Issue -, Pages 332-341

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2016.06.093

Keywords

[emim]Cu2Cl5/NH3; Vapor liquid equilibrium; UNIFAC model; Absorption refrigeration; Thermal performance

Funding

  1. Promotive Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province [B52014NJ021]
  2. National Natural Science Foundation of China [51506104]

Ask authors/readers for more resources

The vapor pressures of [emim]Cu2Cl5/NH3 at ammonia mole fractions (x(1)) ranging from 0.90 to 0.96 at temperatures (T) ranging from 303.15 K to 483.15 K were determined by employing a static method. The correlation of experimental data was calculated by using a modified UNIFAC (Dortmund) model with a total uncertainty of <4.1%. The specific enthalpy of [emim]Cu2Cl5/NH3 binary solution was also calculated on the basis of the predictive excess molar enthalpy of the UNIFAC model. The thermal performance of an absorption refrigeration system with [emim]Cu2Cl5/NH3 as working fluid was simulated. The thermal performance of the [emim]Cu2Cl5/NH3 system is better than those of absorption systems with NH3/H2O, [choline][NTf2]/NH3, [emim][Ac]/NH3, and [emimj[EtOSO3]/NH3 as working fluids. The coefficients of performance and exergy efficiency of the [emim]Cu2Cl5/NH3 system are slightly lower than those of the LiBr/H2O system. The evaporating temperature scope of the former is wider than that of the latter. The [emim]Cu2Cl5/NH3 system also possesses several advantages, including non-crystallization and non corrosion. (C) 2016 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available