4.5 Article

Energy and Economic Assessment of Energy Efficiency Options for Energy Districts: Case Studies in Italy and Egypt

Journal

ENERGIES
Volume 14, Issue 4, Pages -

Publisher

MDPI
DOI: 10.3390/en14041012

Keywords

space heating; space cooling; energy efficiency; renewable energy; energy and economic assessment

Categories

Funding

  1. UK Engineering and Physical Sciences Research Council (EPSRC) [EP/R045518/1]

Ask authors/readers for more resources

This research compares energy efficiency options for energy districts in different climatic areas using a dynamic simulation model based on TRNSYS. The proposed energy efficiency options, including district heating systems and solar energy integration, have been shown to be more effective than baseline scenarios.
In this research, a technoeconomic comparison of energy efficiency options for energy districts located in different climatic areas (Naples, Italy and Fayoum, Egypt) is presented. A dynamic simulation model based on TRNSYS is developed to evaluate the different energy efficiency options, which includes different buildings of conceived districts. The TRNSYS model is integrated with the plug-in Google SketchUp TRNSYS3d to estimate the thermal load of the buildings and the temporal variation. The model considers the unsteady state energy balance and includes all the features of the building's envelope. For the considered climatic zones and for the different energy efficiency measures, primary energy savings, pay back periods and reduced CO2 emissions are evaluated. The proposed energy efficiency options include a district heating system for hot water supply, air-to-air conventional heat pumps for both cooling and space heating of the buildings and the integration of photovoltaic and solar thermal systems. The energy actions are compared to baseline scenarios, where the hot water and space heating demand is satisfied by conventional natural gas boilers, the cooling demand is met by conventional air-to-air vapor compression heat pumps and the electric energy demand is satisfied by the power grid. The simulation results provide valuable guidance for selecting the optimal designs and system configurations, as well as suggest guidelines to policymakers to define decarbonization targets in different scenarios. The scenario of Fayoum offers a savings of 67% in primary energy, but the associated payback period extends to 23 years due to the lower cost of energy in comparison to Naples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available