4.7 Article

Experimental characterization and modeling of boundary conditions and flame spread dynamics observed in the UL-94V test

Journal

COMBUSTION AND FLAME
Volume 225, Issue -, Pages 214-227

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.combustflame.2020.10.054

Keywords

UL-94; Concurrent flame spread; Flame heat flux; Pyrolysis modeling; Oxidative pyrolysis; ThermaKin2D

Funding

  1. Federal Aviation Administration [16-G-017]

Ask authors/readers for more resources

In this study, the UL-94 vertical burning test was characterized by measuring temperature, oxygen content, and heat flux of the burner flame. Tests were conducted using PMMA samples with and without insulated sides, and the results showed significant differences in flame heat flux between the two types of samples. The developed model can be applied to non-charring polymeric solids and further research is needed to explore its applicability for charring and intumescent materials.
To characterize the UL-94 vertical burning test (UL-94 V), temperature, oxygen content, and heat flux of the burner flame were measured using an R-type thermocouple, oxygen analyzer, and water-cooled Schmidt-Boelter gage, respectively. To account for sample geometry, mock samples from Kaowool PM insulation board were used during the burner measurements. Temperature and heat flux measurements were used to express the heat flux of the burner as a linear, piecewise function of burner flame temperature and a constant convective heat transfer coefficient. UL-94 V tests were conducted using 0.27 cm thick poly(methyl methacrylate) (PMMA) samples with and without insulated sides to investigate edge effects. All UL-94 V tests were recorded on video using a 900-nm narrow-band filter to focus on emissions from soot for tracking flame length over time. In some of these tests, a heat flux gage was embedded into the sample to measure PMMA flame heat flux to verify a previously developed laminar wall flame heat feedback submodel. PMMA flame heat fluxes of insulated samples confirmed the wall flame submodel, while non-insulated samples had significantly greater heat fluxes; the flame submodel was scaled accordingly. The burner and wall flame heat flux submodels were combined with an independently developed pyrolysis model of PMMA to conduct two-dimensional, time-resolved simulations of the UL-94 V test. Burner flame oxygen content was measured to be about 5 vol% and was found to enhance PMMA decomposition. Inclusion of the oxygen effect was essential to predict ignition. The simulation predicted flame length and spread on insulated UL-94 V samples reasonably well, validating the submodels. However, the simulation underpredicted flame length on the non-insulated samples; discrepancies were attributed to burning and spread on the edges which were not modeled explicitly. The developed model can be applied to non-charring polymeric solids with no to moderate amount of dripping. Its applicability for charring and intumescent materials will be explored in the future. (C) 2020 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.