4.5 Review

The monitoring of vancomycin: a systematic review and meta-analyses of area under the concentration-time curve-guided dosing and trough-guided dosing

Journal

BMC INFECTIOUS DISEASES
Volume 21, Issue 1, Pages -

Publisher

BMC
DOI: 10.1186/s12879-021-05858-6

Keywords

Vancomycin; Trough; AUC; Nephrotoxicity; Meta-analysis

Ask authors/readers for more resources

This systematic review and meta-analysis investigated the relationship between VCM monitoring strategies and its effectiveness and safety. Findings suggest that VCM trough concentrations and AUC values are correlated with outcomes. AUC-guided monitoring may have potential in reducing nephrotoxicity compared to trough-guided monitoring.
Background This systematic review and meta-analysis explored the relationship between vancomycin (VCM) monitoring strategies and VCM effectiveness and safety. Methods We conducted our analysis using the MEDLINE, Web of Sciences, and Cochrane Register of Controlled Trials electronic databases searched on August 9, 2020. We calculated odds ratios (ORs) and 95% confidence intervals (CIs). Results Adult patients with methicillin-resistant Staphylococcus aureus (MRSA) bacteraemia with VCM trough concentrations >= 15 mu g/mL had significantly lower treatment failure rates (OR 0.63, 95% CI 0.47-0.85). The incidence of acute kidney injury (AKI) increased with increased trough concentrations and was significantly higher for trough concentrations >= 20 mu g/mL compared to those at 15-20 mu g/mL (OR 2.39, 95% CI 1.78-3.20). Analysis of the target area under the curve/minimum inhibitory concentration ratios (AUC/MIC) showed significantly lower treatment failure rates for high AUC/MIC (cut-off 400 +/- 15%) (OR 0.28, 95% CI 0.18-0.45). The safety analysis revealed that high AUC value (cut-off 600 +/- 15%) significantly increased the risk of AKI (OR 2.10, 95% CI 1.13-3.89). Our meta-analysis of differences in monitoring strategies included four studies. The incidence of AKI tended to be lower in AUC-guided monitoring than in trough-guided monitoring (OR 0.54, 95% CI 0.28-1.01); however, it was not significant in the analysis of mortality. Conclusions We identified VCM trough concentrations and AUC values that correlated with effectiveness and safety. Furthermore, compared to trough-guided monitoring, AUC-guided monitoring showed potential for decreasing nephrotoxicity.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available