4.8 Article

Paper-based multiplex analytical device for simultaneous detection of Clostridioides difficile toxins and glutamate dehydrogenase

Journal

BIOSENSORS & BIOELECTRONICS
Volume 176, Issue -, Pages -

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2020.112894

Keywords

Paper-based devices; Clostridioides difficile infection; Antibiotic-resistant bacteria; Multiplex assay; Signal amplification; Point-of-care testing

Funding

  1. Korea Basic Science Institute [C070300, C030110]
  2. Biomedical Research Institute, Jeonbuk National University Hospital
  3. National Research Council of Science & Technology (NST), Republic of Korea [C030110, C180310] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

The newly developed paper-based multiplex analytical device (mPAD) has a unique construction and design that allows for simultaneous detection of glutamate dehydrogenase, toxin A, and toxin B, with high sensitivity and accuracy.
We report a new paper-based multiplex analytical device (mPAD) for simultaneous screening of three analytes (glutamate dehydrogenase, toxin A, and toxin B) known as biomarkers for Clostridioides difficile infection (CDI). To overcome the limitation of common rapid assays (e.g. lateral flow immunochromatographic and enzyme immunoassays) in terms of multiplexing, sensitivity, simplicity, and ease-of-use, the mPAD is constructed with a three dimensional (3D) configuration of paper components with a multi-channel design. Multiple fluidic paths developed with wax-patterned paper allow the simultaneous detection of glutamate dehydrogenase, toxin A, and toxin B without any cross-reactivity. The 3D fluidic network on the mPAD facilitates a self-operating test procedure for the mixing and addition of amplification reagents with a one-step sliding operation. The results of the multiplex CDI assay can be easily interpreted by the naked eye within 10 min, and are visually intensified over time resulting in up to 3-fold signal amplification. Our device exhibited remarkable analytical performances for the simultaneous detection of three CDI biomarkers, providing a sensitivity of 97%, specificity of 88%, accuracy of 95%, and limits of detection for glutamate dehydrogenase, toxin A, and toxin B of 0.16 ng mL(-1), 0.09 ng mL(-1), and 0.03 ng mL(-1), respectively. These results indicate the high applicability and feasibility of mPAD for multiplex testing for CDI with the advantages of being simple, sensitive, inexpensive, user-friendly, and equipment-free.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available